引外接地对降低接地网接地阻抗的作用分析 被引量:1

Function Analysis of Decreasing Grounding Impedance of Ground Grid with Connecting
下载PDF
导出
摘要 引外接地是一种降低地网接地阻抗的有效措施。文中分析了接地网的有效外引长度确定、接地网大小与外引接地有效长度的关系、连接导体半径与引外接地效果的关系等,为引外接地的科学设计和施工提供了依据。  Connecting with exterior grounding conductor is an effective measure to decrease ground grid grounding impedance.To determine the effective length of exterior lead of ground grid,the relation between the ground grid size and the effective length of exterior grounding lead,and the relation between the radius of connecting conductor and the result of exterior grounding were analyzed.The basis for extension conductor's scientific design and construction of exterior grounding was provided.
作者 余祥
出处 《湖北电力》 2007年第5期14-15,共2页 Hubei Electric Power
关键词 引外接地 接地网 接地阻抗 exterior grounding conductor grounding grounding impedance