摘要
ORA(Ocular Response Analyzer)新型眼压计系一种非接触眼压计,它采用自动双向压平测量过程,测量角膜生物力学特性,可消除角膜特性对眼压测量结果的影响,从而更准确地反映真实眼压。本文综述了ORA眼压计的工作原理、测量参数的临床意义及其与青光眼的关系、ORA眼压计与角膜中央厚度的关系,并与其它眼压计进行了比较。
出处
《国际眼科纵览》
2007年第5期307-309,共3页
International Review of Ophthalmology
同被引文献10
-
1唐桂兰,徐永胜,安翠霞,张纯.原发性青光眼患者心理因素分析[J].眼科新进展,2006,26(4):279-282. 被引量:29
-
2Luce DA.Determing in vivo biomechanical properties of the comea with an ocular response analyzer.J Cataract Refract Surg,2005,31:156-162.
-
3ShaH S ,Laicpuzzaman M,Cunliffe l,et al. The use of the Reichert ocular response analyzer to establish the relationship between ocu- htr hysteresis, comeel xesistance factor and central coneal thickness in normal eyes. Cont Lens Amefior Eye,2006,29:257-262.
-
4IGda T,Liu JH,Weinreb RN. Effect of 24-hour corneal biomechan- iced changes on intmocular pressure measuwnent. Invest Ophthal- tool Vis Sci ,2006,47:4422-4426.
-
5Kyaigopoulos M,ScMote T, Kotecha A , ctal. Repeatability of intmocular pressure and corneal biomcchanlcal properties measure- ments by the ocular reponse analyser. Klin Monbl Augenheilkd, 2008,225:357-3600.
-
6Luce DA , Detelmining in vivo biomechanical properties of the cor- neal with an ocular response analyzer. J Cataract Refiact Surg , 2005,31:156-162.
-
7Kirwan CO,Keefe M ,Laniqan B. Corneal hysteresis and intraocu- lar pressure measurement in children using the reichert ocular re- sponse analyzer. Am J Ophthalmol ,2006,142:990-992.
-
8Medeiros FA ,Weimeb RN. Evaluation of the influence d corneal biomochanical properties on intraocular pressure measurements u- sing the ocular response analyzer. J Glaucoma , 2006,15 : 364- 370.
-
9曲建梅,侯建萍,唐桂兰,张纯,安翠霞.原发性青光眼患者术前术后心理特征变化[J].国际眼科杂志,2009,9(1):149-151. 被引量:18
-
10杨颖,周行涛.非接触眼压分析仪(ORA)在准分子激光手术中的应用[J].眼科研究,2010,28(3):285-288. 被引量:3
-
1刘树玉,胡爱清,杨艳芳.两种眼压计测量眼压结果比较[J].护理学杂志(综合版),2004,19(4):49-50. 被引量:1
-
2赵岩,傅铁.复合式小梁切除术后早期非接触眼压计的应用[J].中国误诊学杂志,2003,3(3):367-370.
-
3马云霞,罗雪梅,龚力力,孙仪亚,曾四清.LASIK术前与术后眼压的观测[J].黔南民族医专学报,2005,18(2):79-80. 被引量:2
-
4李惠玲.角膜厚度与近视眼LASIK术后眼内压的关系[J].天津医药,2006,34(7):496-497.
-
5江玉芬,齐雪飞,董晓明.非接触眼压计与Schiotz压陷式眼压计测量眼压结果比较[J].实用临床医学(江西),2010,11(5):84-84. 被引量:2
-
6孙挥宇,彭晓燕,唐忻.Tono-pen眼压计与Goldmann眼压计对玻璃体切割术后患者眼压测量的比较[J].中华眼底病杂志,2005,21(5):303-305. 被引量:2
-
7盛豫,关娟,周历.眼压测定值的分析[J].医学临床研究,2006,23(10):1640-1641.
-
8杨智宽,杜蜀华.Preliminary Studies on the Application of Retinal Thickness Analyzer in the Diagnosis of Glaucoma[J].Journal of Huazhong University of Science and Technology(Medical Sciences),2000,20(3):257-260.
-
9眼压与青光眼[J].国外科技资料目录(医药卫生),1999(5):170-170.
-
10王敏,钱海燕,林方丽,管叶,陈秀云.Icare回弹式眼压计的应用与护理[J].中华现代护理杂志,2011,17(16):1901-1902. 被引量:2