期刊文献+

肝硬化的多层螺旋CT灌注成像研究进展

下载PDF
导出
作者 钟群 张雪林
出处 《肝脏》 2007年第5期414-416,共3页 Chinese Hepatology
  • 相关文献

参考文献18

  • 1范光明,郭启勇.肝脏CT灌注成像的研究进展[J].中国医学影像技术,2004,20(2):298-301. 被引量:21
  • 2马琪,陈昭典.肿瘤学中功能CT成像常用的数学模型[J].国外医学(临床放射学分册),2005,28(5):277-281. 被引量:7
  • 3Hashimoto K,Murakami T,Dono K,et al.Quantitative tissue blood flow measurement of the liver parenchyma:comparison between xenon CT and perfusion CT.Dig Dis Sci,2007,52:943-949.
  • 4Lee TY.Functional CT.Physiological models.Trends Biotech,2002,20:3-10.
  • 5Pandharipande PV,Krinsky GA,Rusinek H,et al.Perfusion imaging of the liver:current challenges and future goals.Radiology,2005,234:661-673.
  • 6Van Beers BE,Leconte I,Materne R,et al.Hepatic perfusion parameters in chronic liver disease:dynamic CT measurements correlated with disease severity.AJR,2001,176:667-673.
  • 7Materne R,Van Beers BE,Smith AM,et al.Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input onecompartmental model.Clin Sci,2000,99:517-525.
  • 8Weidekamm C,Cejna M,Kramer L,et al.Effects of TIPS on liver perfusion measured by dynamic CT.A JR,2005,184:505-510.
  • 9Hashimoto K,Murakami T,Donn K,et al.Assessment of the severity of liver disease and fibrotic change:the usefulness of hepatic CT perfusion imaging.Oncol Rep,2006,16:667-683.
  • 10Kojima H,Tanigawa N,Komemushi A,et al.Computed tomography perfusion of the liver:assessment of pure portal blood flow studied with CT perfusion during superior mesenteric arterial portography.Acta Radiol,2004,45:709-715.

二级参考文献45

  • 1[1]Eastwood JD,Lev MH,Azhari T,et al. CT perfusion scanning with deconvolution analysis:pilot study in patients with acute middle cerebral artery stroke [J]. Radiology,2002,222(1):227-236.
  • 2[2]Furukawa M,Kashiwagi S,Matsunaga N,et al. Evaluation of cerebral perfusion parameters measured by perfusion CT in chronic cerebral ischemia: comparison with Xenon CT [J]. J Comput Assist Tomogr,2002,26(2):272-278.
  • 3[3]Miles KA,Heyball MP,Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT [J]. Radiology,1993,188(2):405-411.
  • 4[4]Blomley MJK,Coulden R,Dawson P,et al. Liver perfusion studied with ultrafast CT [J]. J Comput Assist Tomogr,1995,19(3):424-433.
  • 5[5]Materne R,Van Beers BE,Smith AM,et al. Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J]. Clin Sci,2000,99(6):517-525.
  • 6[6]Cuenod CA,Leconte I,Siauve N,et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT [J]. Radiology,2001,218(2):556-561.
  • 7[7]Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J].Br J Radiol,1991,64(761):409-412.
  • 8[8]Hindmarsh T. Elimination of water-soluble contrast media from the subarachnoid space: investigation with computed tomography [J]. Acta Radiol,1975,346(Suppl):45-49.
  • 9[9]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography [J]. Radiology,1980,137(3):679-686.
  • 10[10]Bader TR,Herneth AM,Blaicher W,et al. Hepatic perfusion after liver transplantation: noninvasive measurement with dynamic single-section CT [J]. Radiology,1998,209(1):129-134.

共引文献109

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部