摘要
文中指出1.8MVA硅铁电炉现行取样法存在的问题是.可信度低,代表性较差,综合精确度远低于国际标准和国家标准。欲使质量检验能切实指导生产,通过理论分析提出了增多份样点、增大份样量和增大产品批量的方案,并通过了实践的验证.
The problems on present sampling method of 1. 8MVA FeSt electricfurnace are that the confidence is low, the representative is not good, overall accuracyis far lower than international and national standars. In order to make quality test reallydirect production, it puts forward plans according to theoretical analyses to increasesampling points, quantity and product lots, and they have been tested and verified.
出处
《铁合金》
北大核心
1997年第3期38-44,30,共8页
Ferro-alloys