期刊文献+

膜反转板式降膜再生器的性能 被引量:1

Performance of plate falling film regenerator with film-inverting configuration
下载PDF
导出
摘要 Plate falling film regenerator with a film-inverting configuration is a new type of regenerator that combines the plate falling film absorption technique with the film-inverting technique.Understanding its performance is very important for industry applications.This paper used a new type regenerator and a plate falling film regenerator for comparison.The design conditions of these two regenerators were the same.By solving the mathematical model,the heat and mass transfer characteristics were calculated and compared between the two regenerators at different flow rates of solution,inlet concentrations,inlet temperatures,generation pressures,and heating conditions.The comparison revealed that these two regenerators had different changes of performance under varying operation conditions.In the case replacing the plate falling film regenerator with the new plate falling film regenerator with film-inverting configuration,the differences in the performance of the regenerators under varying conditions must be taken into consideration. Plate falling film regenerator with a film-inverting configuration is a new type of regenerator that combines the plate falling film absorption technique with the film-inverting technique. Understanding its performance is very important for industry applications. This paper used a new type regenerator and a plate falling film regenerator for comparison. The design conditions of these two regenerators were the same. By solving the mathematical model, the heat and mass transfer characteristics were calculated and compared between the two regenerators at different flow rates of solution, inlet concentrations, inlet temperatures, generation pressures, and heating conditions. The comparison revealed that these two regenerators had different changes of performance under varying operation conditions. In the case replacing the plate falling film regenerator with the new plate falling film regenerator with film-inverting configuration, the differences in the performance of the regenerators under varying conditions must be taken into consideration.
出处 《化工学报》 EI CAS CSCD 北大核心 2007年第11期2816-2821,共6页 CIESC Journal
基金 国家自然科学基金项目(50576056) 上海市重点学科建设项目(T0503)~~
关键词 传热传质 再生器 性能 降膜 膜反转 heat and mass transfer regenerator performance falling film film-inverting
  • 相关文献

参考文献15

二级参考文献27

  • 1刘振义,徐尧润,宋继田.异形板外流降膜蒸发器及其研究[J].食品与机械,1995,11(3):19-21. 被引量:10
  • 2王长庆.溴化锂降膜式发生器的传热传质研究[M].上海:上海交通大学动力与能源工程学院,1996..
  • 3王长庆,学位论文,1996年
  • 4杨强生,对流传热与传质,1985年
  • 5Reay D A. Compact heat exchangers, enhancement and heat pumps [ J ]. Int. J. Refrigeration, 2002, ( 25 ): 460-470.
  • 6Glebov D, Setterwall F. Experimental study of heat transfer additive influence on the absorption chiller performance[J]. Int. J. Refrigeration,2002, (25) :538-545.
  • 7Flamensbeck M, et. al, A cost effective absorption chiller with plate heat exchangers using water and hydroxides[J]. Applied thennal engineering, 1998,18: 413-425.
  • 8陈亚平.交叉双尺度波纹片上溴化锂降膜吸收器实验研究[A]..中国工程热物理学会传热传质学学术会议论文集[C].上海:工程热物理学报,2002..
  • 9Islam Md R, Wijeysundera N E, Ho J C. Performance study of a falling film absorber with a film-inverting configuration[ J ]. Int. J. Refrigeration, 2003, (26): 909-917.
  • 10Kesslling W, Laevemann E, Kapfhammer C. Energy storage for desiccant cooling systems component development[J]. Solar Energy, 1998, 64(4-6): 209 -221.

共引文献19

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部