摘要 文章讨论了化学灌浆在威海市垃圾处理厂截污坝防渗帷幕中的应用及效果。截污坝是垃圾处理厂的主要部分,其防渗能力直接关系工程的优劣。采用水泥灌浆后所做的压水试验证明,岩土的渗透性能虽然得到改善,但是达不到设计要求。尔后通过中间夹单排化学灌浆补强的布孔形式改进了施工工艺,进行了防渗的再处理。结果表明,结合化学灌浆后大大提高了岩体的防渗能力,效果明显,达到了设计要求。 This paper discusses the application and effect of chemical grouting in seepage proof curtain of interception--pollutant dam of Weihai waste treatment plant. Interception pollutant dam is the main part of waste treatment plant, and its seepage capabilities di- rectly influence the effect of engineering construction. The water pressure test after adop- ting cement grouting proves, although the permeability of rock improves, it can not achieve the design requirement. Then by reinforcing the chemical grouting by means of clipping single row in middle, this bunch hole patterns improve construction technology and treats the seepage again. The result indicates that the seepage capability of rocks increases greatly associating with chemical grouting.
出处 《工程地球物理学报》 2007年第5期501-505,共5页 Chinese Journal of Engineering Geophysics
关键词 化学灌浆 防渗帷幕 水泥灌浆 防渗能力 chemical grouting seepage proof curtain cement grouting seepage capability
  • 相关文献

参考文献2

二级参考文献11

  • 1李茂芳 孙钊.大坝基础灌浆[M].北京:水利电力出版社,1987..
  • 2毛晓圆.水玻璃耐酸混凝土[M].北京:冶金工业出版社,1985..
  • 3李茂芳,大坝基础灌浆,1987年
  • 4毛晓圆,水玻璃耐酸混凝土,1985年
  • 5谭日陞.丙烯酸盐化学灌浆材料的研究及应用[A].工程岩石力学[C].武汉:武汉工业大学出版社,1998.503—511.
  • 6魏涛 董建军.f1096断层自下而上深孔高压化学灌浆[J].湖南大学学报,2004,(4):76-76.
  • 7陈昊.化学水泥复合灌浆技术在三峡工程永久船闸基础f1050断层加固处理中的应用[J].湖南大学学报,2004,(4):94-94.
  • 8陈磊 朱虹.三峡升船机上闸首基础F548断层化学灌浆加固处理[J].湖南大学学报,2004,(4):90-90.
  • 9谭日升,蒋硕忠,薛希亮.三峡大坝化学灌浆研究[J].长江科学院院报,2000,17(6):4-8. 被引量:16
  • 10陈珙新,祝红,熊进.三峡工程F_(215)断层复合灌浆处理试验研究[J].长江科学院院报,2000,17(6):9-11. 被引量:18

共引文献10

同被引文献10

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部