摘要
目的建立污水和尿液中全氟辛酸(PFOA)的柱前紫外衍生一高效液相色谱测定方法。方法样品中的PFOA与四丁基氢氧化铵形成的离子缔合物被甲基叔丁基醚萃取后,与ω-溴苯乙酮在乙腈中衍生成具有紫外吸收的物质,高效液相色谱-紫外可见检测器检测。结果方法检出限可达7.0μg/L;相对标准偏差(RSD)〈10%;样品的回收率在85.3%~116%之间。结论本法适用于测定水样及尿液中的全氟辛酸。
Objectives To establish a reversed phase high performance liquid chromatographic method with pre-column ultraviolet derivatization for the determination of perfluorooctanoic acids (PFOA) in sewage and urine. Methods PFOA in sewage and urine formed an ion-pair with tetrabutylammonium (TBA) and were extracted into MTBE. The PFOA then reacted with co-bromoacetophenone (ω-BAP) in acetonitrile and produced materials quantifiable by HPLC with UV detector. Results The detection limit of the proposed method was 7.0μg/L with a relative standard deviation of less than 10%. The recoveries for real samples ranged from 85. 3% to 116%. Conclusion The proposed method is suitable for the determination of PFOA in sewage and urine.
出处
《四川大学学报(医学版)》
CAS
CSCD
北大核心
2007年第6期1037-1039,共3页
Journal of Sichuan University(Medical Sciences)
关键词
全氟辛酸
高效液相色谱法
柱前紫外衍生
Perfluorooctanoic acid HPLC Pre-column ultraviolet derivatization