摘要 目的探讨国产微柱凝胶抗人球蛋白不规则抗体筛检卡(以下简称:筛检卡)对血清(浆)中不规则抗体的检出效能。方法用筛检卡与凝聚胺法同时筛检IgG类抗C、抗c、抗D、抗E4种标准抗血清,并比较结果;取334份有免疫史或怀疑有新生儿溶血病的患者血清(浆),同时用两法筛检,结果用统计学处理。结果两法对IgG类4种标准抗血清的筛检结果(阴性、阳性)完全一致;但两法阳性凝集强度有部分不同。334份血清(浆)筛检卡检出9例不规则抗体阳性,凝聚胺法检出7例,两法不规则抗体检出差异无统计学意义(P>0.05),在两法共同检出的7例中,有2例筛检卡凝集强度高于凝聚胺法。结论国产筛检卡血清(浆)不规则抗体筛检结果可靠、操作简便,可常规应用,尤其适用于大批量标本的筛检。 Objective To explore the detection efficacy of domestic anti-globulin irregular antibodies mieroeolumn gel test screening cards( abbreviated to screening cards ) for screening erythroeytie irregular antibodies in serum (plasma). Methods Four kinds of IgG antibodies standard antiserums including anti-C, anti-e, anti-D and anti-E were screened using screening cards and polybrene kits simultaneously. 334 serum(plasma) samples from patients with immune disease history or suspected hemolytic disease of the newborn were screened using screening cards and polybrene kits simultaneously. All results were analyzed by statistics method. Results ( 1 ) The screening results ( positive or negative) of two methods for first contrasting experiment were totally uniform except for the different intensity of positive agglutination partly. (2)9 irregular antibodies positive serum (plasma) samples were screened out using screening cards and 7 were screened out using polybrene kits for next contrasting experiment. The distinction between two methods for screening irregular antibodies was no significant difference( P 〉 0.05 ) and the 2 samples among 7 samples screened out by two methods had higher agglutination intensity detected by screening cards than that by polybrene method. Conclusions Domestic anti-globulin irregular antibodies mieroeolumn gel test screening cards has advantages such as reliable results and convenient manipulation, it can be used for conventional practice and especially for screening a large number of samples.
出处 《实用全科医学》 2007年第11期1012-1013,共2页 Applied Journal Of General Practice
关键词 微柱凝胶抗人球蛋白试验 不规则抗体筛检 凝聚胺试验 Anti-globulin microcolumn gel test Irregular antibodies sereening Polybrene test
  • 相关文献

参考文献4

二级参考文献27

  • 1张松,陈少芬,郭淑丽,郭伟,程淑华,赵宏平.几种配血方法的比较[J].中国输血杂志,1996,9(4):197-197. 被引量:7
  • 2[1]Bromilow IM . The use of the monoclonal antibodies for blood typing and antibody screening by the gel test [J]. Vax Sang,1996,70:49.
  • 3[2]Knight RC,Pool GD . Detection of cell antibodies: Current and future techniques[J].Br J Biomed,1995,52:297.
  • 4[3]De Castilho, et al.Evaluation of recent techniques for detection of blood cell antibodies in sera of reference samples,patients, pregnant woman,and blood clonors [J].J CIm Lab Anal,1996,10:250.
  • 5Rainer Lynen, Olaf Krone, Tobies J Legler, et, al. A newly developed gel centrifugation test for quantification of RBC - bound IgG antibodies and their subclasses IgG1 and IgG3: comparison with flowcytometry. Transfusion, 2002, 42 (5): 612.
  • 6Shattil SJ, Cunningham M. Hoxie JA. Detection of activated platelets in whole blood using activation-dependent moneclonal antibodies and flowcytomtry. Blood, 1987, 70 (1): 307.
  • 7秦红群 杜锦池 沙成汉.Polybrene法交叉配血4538例结果分析[J].中国输血杂志,1998,11(2):102-102.
  • 8胡宁克 徐伟人 刘达庄.四种检测红细胞血型IgG抗体方法的比较[J].临床检验杂志,1999,17(1):39-39.
  • 9Lalezari P,Jiang AF.The manual polybrene test:a simple and rapid procedure for detection of red cell antibodies.Transfusion,1980,20 (2):206
  • 10Lalezari P.A new method for the detection of red cell antibodies.Transfusion,1968,8(6):372

共引文献90

同被引文献17

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部