摘要 20世纪中后期.影像引导系统(image-guid-ance)逐渐被引入外科手术过程。由于对高精度的特殊要求.使得影像引导技术被神经外科医师最早接受并大力发展。20世纪90年代,伴随现代计算机技术和定位跟踪技术的发展.连结现代影像技术和显微神经外科手术技术的桥梁——神经导航系统(neuronayigation)出现,短短几年中不断完善普及,与同时出现的“锁孔”手术技术相结合,使神经外科手术观念发生了质的飞跃,进入了微创手术时代。
作者 赵继宗 王嵘
出处 《北京医学》 CAS 2007年第11期687-690,共4页 Beijing Medical Journal
  • 相关文献

参考文献25

  • 1Brown RA,Roberts TS,Osborn AG.Stereotaxic frame and compuler software for Ctdirected neurosurgical localization.Invest Radio 1980,15:308-312.
  • 2Raj Sindwani MD,Richard D,Bucholz MD.The next generation of navigational technology.Otolaryngol Clin North Am,2005,38:551-562.
  • 3Tirakotai W,Sure U,Benes L,et al.Inage-guided transsylvlan,transinsular approach for insular cavernous angionm.Neurosurgery,2003,53:1299-1304.
  • 4akajima S,Atsumi H,Bhalerao AH,et al.Computer-assisted surgical planning for cerebrovascular neurosurgery.Neumsurgery,1997,41:403-410.
  • 5Zamorano L,Planells M,Jiang Z,et al.Vascular malformations of the brain:surgical management using interactive image guidance.Neurosurg Clin N Am,1996,7:201-214.
  • 6Lucas C,Zabramsk J,Spetzler R,et al.Treatment of intracranial dural arteriovenous malformations:a meta-analysis from the English language literature.Neurosurgery,1997,40:1119-1132
  • 7Vougioukas1 VI,Coulin1 CJ,Shah1 M,et al.Benefits and limitations of image guidance in the surgical treatment of intracranial dural arteriovenous fistulas.Acta Neurochir (Wien),2006,148:145-153.
  • 8Tomak P,Cloft H,Kaga A,et al.Evolution of the management of tentorial dural arteriovenous malformations.Neurasurgery,2003,52:750-760.
  • 9Coley S,Bomanowski C,Hedgson T,et al.Dural arteriovenous fistulae:noninvasive diagnosis with dynamic MR digital subtraction angiography.Am J Neuroradiol,2002,23:404-407
  • 10Kai Y,Hamada J,Morioka M,et al.Correlation between magnetic resonance images and draining patterns in dural arteriovenous fistulas with leptomeningeal venous drainage.Acta Neurochir (wien),2000,142:413-418

二级参考文献31

  • 1[1]Nimsky C,Ganslandt O,Cerny S,et al.Quantification of ,visualization of ,and compensation for brain shift using intraoperative magnetic resonance imaging.Neurosurgery,2000,47:1070~1079.
  • 2[2]Jodicke A,Deinsberger W,Erbe H,et al.Intraoperative three-dimensional ultrasonography:an approach to register brain shift using multidimensional image processing.Minim Invasive Neurosurg,1998,41:13~19.
  • 3[3]Haberland N,Ebmeier K,Hliscs R,et al.Neuronavigation in surgery of intracranial and spinal tumors.J Cancer Res Clin Oncol,2000,126:529~541.
  • 4[4]Fahlbusch R,Ganslandt O,Nimsky C.Intraoperative imaging with open magnetic resonance imaging and neuronavigation.Childs Nerv Syst,2000,16:829~831.
  • 5赵继宗,中华医学杂志,2001年,81卷,323页
  • 6Roberts DW, Strohbehn JW, Hatch JF ,et al. A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope .J Neurosurg, 1986,65:545-549.
  • 7Hill DL, Hawkes DJ, Gleeson MJ, et al. Accurate frameless registration of MR and CT images of the head: application in planning surgery and radiation therapy. Radiol, 1994,191:447-454.
  • 8Patel N, Sandeman DR, Cobby M, et al. Interactive image-guided surgery of the spine-use of ISG/Elekta viewing wand to aid intraoperative location of a sacral osteoblastoma. British J Neurosurg,1997,11:60-64.
  • 9Welch WC, Subach BR, Pollack IF ,et al. Frameless stereotatic guidance for surgery of the upper cervical spine instrumentation application. Neurosurg, 1997, 40:958-964.
  • 10Braun V,Rath SA, Antoniadis G, et al. In vivo experiences with frameless stereotactically guided screw placement in the spine-results from 75 consecutive cases. Neurosurg Rev, 2001,24:74-79.

共引文献56

同被引文献152

引证文献14

二级引证文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部