摘要 对一台空气源热电热泵低温热水装置在不同工作条件下的性能进行了实验研究.研究结果表明:随着工作电压升高,制热系数减小,但热水加热时间会缩短;在环境温度较低时,随着热水温度的升高,冷端吸热量有可能减少,而在环境温度较高时,冷端吸热量随着热水温度的升高而一直增大;环境温度越高,冷端温度也就越高,冷热端温差就越小,制热系数就越大;在电压为117 V、热水温度为35℃、环境温度为30℃时的制热系数为1.68,而环境温度为5℃时的制热系数仅为1.22.此项研究可为热电热泵热水装置的设计和应用提供参考. The performance of the thermoelectric heat pump low-temperature water heater was investigated under various operating conditions. The experiment results show that the coefficient of performance decreases and the heating time shortens with the increase of the applied voltage. At low ambient temperatures, the heat absorbed from ambient air may decrease with the increase of the temperature of hot water. However, at high ambient temperatures, the heat absorbed always increases with the increase of the temperature of hot water. The higher the ambient temperature is, the higher the cold side temperature is and the smaller the temperature difference between the hot and cold sides becomes, leading a larger coefficient of performance. Under an applied voltage of 117 V and a hot temperature of 35 ℃, the coefficient of performance with an ambient temperature of 30 ℃ is 1.68, and the coefficient of performance with an ambient temperature of 5 ℃ is only 1.22.
出处 《西安交通大学学报》 EI CAS CSCD 北大核心 2007年第11期1338-1341,共4页 Journal of Xi'an Jiaotong University
关键词 热电热泵 热水装置 制热系数 thermoelectric heat pump water heater coefficient of performance
  • 相关文献

参考文献10

  • 1杨文帅,王荣光,凌继红,张于峰.地板辐射供暖在生理卫生方面的特点[J].煤气与热力,2002,22(2):151-152. 被引量:29
  • 2Huang B J, Chin C J, Duang C L. A design method of thermoelectric cooler[J]. International Journal of Refrigeration, 2000, 23(3): 208-218.
  • 3Xuan X C. Investigation of thermal contact effect on thermoelectric coolers [J ]. Energy Conversion and Management, 2003, 44 (3): 399-410.
  • 4宣向春,王维扬.半导体制冷器工作参数的理论分析[J].低温工程,1998(1):26-30. 被引量:6
  • 5Dai Y J, Wang Ruzhu, Ni L, Experimental investigation and analysis on a thermoelectric refrigerator driven by solar cells [J]. Solar Energy Materials &. Solar Cells, 2003, 77 (4): 377-391.
  • 6Luo Qinghai, Tang Gangfa, Liu Zhiqiang, et al. A novel water heater integrating thermoelectric heat pump with separating thermosiphon [ J ]. Applied Thermal Engineering, 2005, 25 (14/15): 2193-2203.
  • 7张华俊,陶文铨,冯倩莹,董晓俊,邹挺,赵爱国,邱传惠.风冷热电空调器实验研究[J].流体机械,1999,27(2):48-51. 被引量:1
  • 8Riffat S B, Omer S A, Ma Xiaoli, A novel thermoelectric refrigeration system employing heat pipes and a phase change material: an experimental investigation [J]. Renewable Energy, 2001, 23 (2): 313-323.
  • 9李茂德,卢希红.热电制冷过程中散热强度对制冷参数的影响分析[J].同济大学学报(自然科学版),2002,30(7):811-813. 被引量:52
  • 10Omer S A, Riffat S B, Ma Xiaoli. Experimental investigation of a thermoelectric refrigeration system employing a phase change material integrated with thermal diode (thermosyphons) [J]. Applied Thermal Engineering, 2001, 21 (12): 1265-1271.

二级参考文献7

共引文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部