摘要 利用有限元软件对1 100 kVGIS隔离开关气室及故障接地开关气室进行三维电场分析计算.针对复杂的分析实例,采用不同的参数设置进行网格划分,同时对结构复杂区域进行子建模以放大复杂区域.获得不同开距下隔离开关气室电场强度分布和动触头表面电场强度分布曲线.通过分析电场强度结果,得出不同开距下隔离开关气室内电场强度较大的位置及其电场强度比值.分析故障接地开关气室中盆式绝缘子表面的电场分布情况,结果表明,盆子端部倒角处尺寸对电场强度影响较大,从而为隔离开关气室及故障接地开关室的结构设计提供理论依据. Three dimensional electric field of 1 100 kV SF6 disconnector cabinet and fault earthing switch cabinet was analyzed using the finite element software. For the complex analysis examples, the models were meshed by different parameter settings, and the regions of complex structure were rebuilt for amplifying dangerous regions. Distribution of electrical field intensity and curves of electrical field intensity distribution of dynamic contact surface in the disconnector cabinet under different gap lengths were obtained. The positions of higher intensity and their intensity values under different gap lengths in the disconnector cabinet were acquired according to the result analysis. The distribution of electrical field intensity of insulator surface in fault earthing switch cabinet was analyzed. It has been found that the dimension of insulator end has a great effect on electric field intensity. The present research can supply the theoretical basis for construction design of disconnector cabinet and fault earthing switch cabinet.
出处 《沈阳工业大学学报》 EI CAS 2007年第5期524-528,533,共6页 Journal of Shenyang University of Technology
基金 教育部科技创新工程重大项目培育基金资助项目
关键词 三维电场 电场强度 特高压 隔离开关气室 故障接地开关气室 three dimensional electric field electric field inter^sity extra-high voltage disconnector cabinet fault earthing switch cabinet
  • 相关文献

参考文献9

二级参考文献27

  • 1何俊佳,邹积岩,张汉明,程礼椿.真空灭弧室耐压水平的改进和提高[J].高电压技术,1996,22(2):50-53. 被引量:6
  • 2金黎,王季梅.真空灭弧室向高电压大容量发展的关键问题[J].真空电子技术,1996,9(1):50-54. 被引量:1
  • 3[1] Trowbridge C W.Electromagnetic computing:the way ahead[J].IEEE Trans,on MAG,1988,24(1):13-18.
  • 4[2] Meijerink J A,Van der vorst H A.An iterative solution method for linear systems of which the coefficient matrix is a symmetric M-Matrix[J].Mathematics of Computation,1977,31(1):148-162.
  • 5马志瀛.积极开展高电压真空灭弧及126kV以上真空断路器的理论研究和产品开发[J].电气技术,2002,(5):1-3.
  • 6冯慈章.电磁场[M].北京:高等教育出版社,1991..
  • 7任中毅 官国利.气体绝缘[M].哈尔滨:哈尔滨电工学院印刷厂,1993..
  • 8刘笙.电气工程基础[M].北京:科学出版社,2002..
  • 9Swanson B W,Roidt R M.Boundary layer analysis of SF6 circuit breaker arc[J].IEEE Trans.on PAS,1972,91:1086.
  • 10Yan J D,Fang M T C,Hall W.The development of PC based CAD tools for auto-expansion circuit breaker design[J].IEEE Trans.on Power Delivery,1999,14(2):176-181.

共引文献146

同被引文献175

引证文献22

二级引证文献231

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部