准圆锥摆运动中摆角的测量

Measuring of the Pendulum Angle of Quasi-Taper Swinging Movement
下载PDF
导出
摘要 借助3个位移传感器,利用矢量积推导出一种近似算法,实现了准圆锥摆运动中摆角的测量.针对实际应用中测量结果误差较大(介于±0.10°)的问题,从计算公式的近似误差、传感器的倾角、传感器的灵敏度变化和零位漂移以及设备的机械加工和装配精度4个方面,分析了它们对于测量结果的影响,得出误差主要来源于传感器的灵敏度变化.给出了后续改进方案,使得测量精度提高到±0.02°的范围. With three displacement sensors, an approximate algorithm derived from vector product was given to measure the pendulum angle of quasi-taper swinging movement. For the problem that the measurement results have greater error in practice (within the range of ±0. 10°), four respects which may influence the measurement were analyzed: approximate error of the formula, leaning angles of the sensors, sensitivity changing and zero drift of the sensors and precision of the parts and their assembly. It was concluded that the error mainly stems from the sensitivity changing of the sensors. The improvement was made to enhance the precision of measurement within the range of ±0.02°.
作者 王灯照 钱静
出处 《江南大学学报(自然科学版)》 CAS 2007年第5期583-587,共5页 Joural of Jiangnan University (Natural Science Edition) 
关键词 矢量积 准圆锥摆运动 摆角 vector product quasi-taper swinging movement pendulum angle
  • 相关文献

参考文献6

二级参考文献9

  • 1戴仁慈,李生强,胡嘉增,林绵中,陆荣庆.电解液式倾斜传感器及其数据处理系统[J].应用科学学报,1989,7(4):341-345. 被引量:5
  • 2柳洁.怎样解释锥摆公式“cosθ>1”的出现[J].物理通报,1985,(6):25-25.
  • 3巫强生.对怎样解释锥摆公式中“cosθ>1”的出现,一文的异解[J].物理通报,1986,(12):25-25.
  • 4郭蔚兴.双轴气泡传感器自动按平系统[J].测绘学报,1986,4(2):27-29.
  • 5马良理.应变电测与传感技术[M].北京:中国计量出版社,1992.171-174.
  • 6马良理,应变电测与传感技术,1992年,171页
  • 7郭蔚兴,测绘学报,1986年,4卷,2期,27页
  • 8季长路,张家钰.激光基准信标仪的研制[J].安徽机电学院学报,2000,15(1):31-34. 被引量:4
  • 9聂福全.国外振动压路机设计的发展趋势[J].机械产品与科技,2003(1):2-5. 被引量:3

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部