摘要
针对娘子关电厂3号锅炉频繁灭火的问题,从结焦和燃烧不稳两方面进行了原因分析。通过燃烧优化调整试验,提出了针对性的防治措施,使锅炉的灭火次数大大减少,经济性和安全性得到了明显的提高。
The cause of No.3 boiler frequent outfire in Niangziguan power station is analyzed from slagging and instable combustion. After combustion control test, the effective measures are presented. The boiler outfire frequency is reduced and the economy and security is improved obviously.
出处
《电站系统工程》
北大核心
2007年第6期25-27,共3页
Power System Engineering
关键词
锅炉
结焦
灭火
燃烧调整
boiler
slagging
outfire
combustion control