摘要 在前期研究结果的基础上,编制了高强混凝土轴压柱和偏压柱准耐火极限的计算程序,考查了高温爆裂对准耐火极限的影响,研究了柱截面尺寸、轴压比、配筋率和偏心距等参数对高强混凝土柱准耐火极限的影响规律,结果表明:高温爆裂对高强混凝土柱准耐火极限的影响明显,截面尺寸、轴压比和偏心距的影响较大,而配筋率的影响较小。 On the basis of prior research result, the program of quasi fire endurance on axial and eccentric compressive column is developed, and the effect of explosive spalling under high temperature is consid- ered. The effect of different parameters on quasi fire endurance is studied, including cross - section dimension, axial pm-loading ratio, longitudinal steel ratio and eccentricity. The results show that the explosive spalling has an obvious effect on quasi fire endurance of high strength concrete column. Cross - section dimension, axial pre - loading ratio and eccentricity has obvious influence on the quasi fire endurance of high strength concrete column, and longitudinal steel ratio has less effect.
作者 袁杰 马晓燕
出处 《低温建筑技术》 2007年第4期1-4,共4页 Low Temperature Architecture Technology
基金 国家自然科学基金资助项目(59678034)
关键词 高强混凝土柱 火灾 爆裂 准耐火极限 high strength concrete column fire explosive spalling quasi fire endurance
  • 相关文献

参考文献6

  • 1GB 50016-2006,建筑设计防火规范[S].
  • 2安部武雄,古村福次郎,筱原保二.高温度における高強度コンワリ一トの力學的性質に關する實驗的研究[M].日本:日本建築學會大會學術講演梗概集(東北),1991.
  • 3Carlos Castillo,A J Durrani.Effect of transient high temperature on high-strength concrete[J].ACI Materials Journal,1990,87(1):47-53.
  • 4安部武雄,古村福次郎,户祭邦之,黑羽健嗣,小久保勸.高温度における高強度コンワリ一トの力學的特性に關する基礎的研究[C].日本建築學會構造系論文集,第515號,1999.
  • 5吴波,袁杰,王光远.高温后高强混凝土力学性能的试验研究[J].土木工程学报,2000,33(2):8-12. 被引量:104
  • 6吴波,袁杰,李惠,周文松.高温下高强混凝土的爆裂规律与柱截面温度场计算[J].自然灾害学报,2002,11(2):65-69. 被引量:24