摘要 压缩活塞与排出器的位移大小及相位差对自由活塞斯特林制冷机的制冷性能具有极其重要的影响。文中通过对目前各种位移测试方法优缺点分析,结合自由活塞式斯特林制冷机自身特点,提出了采用应变片响应涡旋柔性弹簧形变来测量活塞和排出器位移的新方法。通过分析、设计和标定,建立了一套基于应变片的自由活塞斯特林制冷机位移测量系统。实验测试结果表明,该位移测量系统是可靠的,具有体积小、投资省等优点,且不需要特别的安装空间。 The displacements and phase shift of piston and displacer have important effects on the performance of free - piston Stifling cooler, in this paper, at first, the merits and faults of various displacement measurement methods at present were detailedly analysed. According to structure characteristics of free -piston Stirring cooler, a new displacement measurement method was put forward, that strain foils were used to measure indirectly the displacements of piston and displacer by responding to shape change of spiral flexure spring. After finishing analysis, design and calibration to strain foil, the displacement measurement system based on strain foil was built up for free - piston Stifling cooler. The experimental testing results indicate that the displacement measurement system is reliable, simpler and cheaper, which needs not special installation site.
出处 《低温与超导》 CAS CSCD 北大核心 2007年第5期383-386,共4页 Cryogenics and Superconductivity
基金 上海高校培养优秀青年教师科研专项基金
关键词 自由活塞斯特林制冷机 位移测试 应变片 Free- piston Stirring cooler (FPSC), Displacement measurement, Strain foil
  • 相关文献

参考文献4

  • 1Park S J, Hong Y J, Kim H B, et al. An experimental study on the phase shift between piston and displacer in the Stirling cryocooler. Current Applied Physics, 2003,3:449 -455.
  • 2Reed J S. A capacitance based axial position sensor for cryocoolers. Cryogenics, 2005,45:225 - 230.
  • 3Yang Y P, Huang B J, Chen F M, et al. New techniques for the non- contact measurement of displacer motion of a miniature split-Stirling cryoeooler. Cryogenics, 1996,36:573 - 578.
  • 4严钟豪.非电量电测技术[M].北京:机械工业出版社,1989..

共引文献3

同被引文献33

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部