期刊文献+

石墨炉原子吸收法直接测定血清中硒的方法研究 被引量:2

Determination of selenium in serum by electrothermal atomic absorption spectrometry
下载PDF
导出
摘要 目的:建立测定血清中硒的新方法。方法:应用Triton X-100稀释样品,横向塞曼石墨炉原子吸收光谱法直接测定样品中痕量硒。结果:选定了最佳测量条件,该方法的灵敏度、精密度均能满足检测工作的需要。本法对硒的最低检出量为14.7 pg,回收率在90%~102%之间。结论:本法简便、快速、准确,灵敏度和精密度高,适用于血清中硒的测定。 Objective :To establish a new method for determination of selenium in serum. Methods :The samples were diluted in a medium containing Triton X - 100 before being introduced directly into the furnace and then detected by Zeeman GFAAS. Results:Under the best condition, the sensitivity and precision were suitable for the determination while the rate of recovery was controlled between 90% to 100%. The lowest detection limit of serum was 14. 7 pg. Condusion:This method is simple, quick, accurate and sensitive. It is a very good method for measuring selenium in serum.
出处 《中国卫生检验杂志》 CAS 2007年第11期2001-2002,共2页 Chinese Journal of Health Laboratory Technology
关键词 横向塞曼 GFAAS 全血 Landscape orentation zeeman GFAAS Serum Selenium