摘要
简介了邯钢引进的35000 m3/h制氧机内压缩流程空分设备的流程和性能参数,详细分析了粗氩塔发生氮塞的原因,阐述了为消除氮塞而采取的措施。
The flow and specifications of a 35000 m^3/h air separation unit with internal compression flow have been introduced. After detailed cause analysis of nitrogen block in raw argon column, the measures for eliminating the fault have been described.
出处
《低温与特气》
CAS
2007年第5期21-22,共2页
Low Temperature and Specialty Gases
关键词
内压缩流程
粗氩塔
氮塞
措施
internal compression flow
raw argon column
nitrogen block
measure