摘要
近几年来,喷水减温器的混合管出现了变形损坏等事故。本文对事故原因进行了分析,认为这是由于混合管内外压差过大所引起。对此作者提出了三条改进意见。
Deformation failures of mixing tubes in spray attemperaters, which happneed in recent years, are analysed with the conclusion that the reason is the excessive pressure differen- re across the tube wall. Three improvement suggestions are presented.
出处
《动力工程》
CSCD
1989年第2期49-51,共3页
Power Engineering