摘要
应用等效热降法对该机组的化学补充水系统,过热器减温水系统,再热器减温水系统,低压加热器疏水泵系统及锅炉连续排污系统进行定量分析与改进。
Using equivalent enthalpy drop technique,systens of the unit for Chemical makeup water,superheater dropping temperature water,reheater dropping temperature water, low-pressure heater condensate pump,boiler continous drainage are analysed quantitatively and modified. A good benifit is gained in this paper.
关键词
热力系统
节能
发电厂
发电机组
Thermodynamic system Energy saving Analysis Improvement