摘要
本文论证了利用CCD测定X射线胶片和增感屏调制传递函数的可行性,并给出了一种适用于CCD测试数据的处理方法。对于同一种X射线胶片和增感屏,分别给出了测微光密度计和CCD两种测量数据及其误差分析,并且对几种不同的增感屏和胶片性能做了评价。从实际应用中指出利用CCD探头测量调制传递函数的优越性。
It is feasible that to use CCD device and image processing system in measurement of the modulation transfer function (MTF) of X-ray film and luminescent screen. A method for processing data captured by CCD is given also. At the same time, the data measured by CCD and APD respectively and their errors are given. For a few kinds of luminescent screens and film, the comparison and evaluation are completed. From the practice of MTF measurement, the advantages of using CCD have been given.
出处
《计量学报》
CSCD
北大核心
1997年第3期187-191,共5页
Acta Metrologica Sinica