摘要 采用高效液相色谱法同时检测了64个卷烟滤嘴成型纸、接装纸样品中的荧光增白剂ABP、VBL含量。即先用紫外灯照射纸样品,而后用N,N-二甲基甲酰胺提取显示荧光的样品,提取液经Alltima C18柱(150mm×4.6mm×5μm)色谱分离和甲醇水(体积比45:55,流速1.0mL/min)混合液洗脱,在波长435nm下检测。结果显示:①ABP、VBL的捡出限分别为0.10、0.15ng/mL,平均回收率101.0%~102.1%、102.0%-~04.2%,RSD 0.66%~2.48%、0.89%~1.84%;②60个纸样在紫外光下没有荧光;③4个有荧光的纸样中均未检出ABP,而都检出了VBL,其中,1个为接装纸样品,3个为成型纸样品。该法适用于批量卷烟滤嘴成型纸和接装纸中荧光增白剂ABP、VBL的同时测定。 The fluorescent whitening agents, ABP and VBL, in 64 samples of tipping paper and plug wrapper were determined with HPLC. The samples were irradiated by UV-lamp, and the samples which fluoresced were extracted with N, N - dimethylformamide. The resultant extract was passed through an Alltima C18 column (150 mm ×4.6 mm ×5 μm) using methanol-aqueous solution (45: 55, v/v) as mobile phase at a flow rate of 1. 0 mL/min, and detected at the wave length of 435 nm. The results showed that: 1 ) the average recoveries of ABP and VBL were 101.0% to 102.1% and 102.0% to 104. 2% with RSD of 0. 66% to 2.48% and 0. 89% to 1. 84% at detection limits of 0.10 and 0.15 ng/mL, respectively; 2) 60 samples did not fluoresce under UV- lamp ; 3) VBL was detected in the other 4 samples which fluoresced, while ABP was not ; among the 4 samples, 1 was tipping paper and 3 were plug wrapper. The method is suitable for the simultaneous determination of ABP and VBL in batches of plug wrapper and tipping paper samples.
出处 《烟草科技》 EI CAS 北大核心 2007年第11期40-44,共5页 Tobacco Science & Technology
基金 国家烟草专卖局基金资助项目"卷烟材料安全性研究--滤嘴用卷烟材料中有害无机元素的分析研究"(110200201033)
关键词 卷烟 接装纸 成型纸 荧光增白剂 高效液相色谱法 Filter Tipping paper Plug wrapper Fluorescent whitening agent High performance liquid chromatography (HPLC)
  • 相关文献

参考文献11

二级参考文献15

共引文献52

同被引文献493

引证文献44

二级引证文献308

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部