摘要 目的总结计算机导航定位与常规定位手术在膝关节表面置换术治疗膝关节骨性强直两组病例的疗效差异。方法对比计算机导航定位与常规定位人丁膝关节表面置换术后两组病例的力线、软组织平衡、并发脂肪栓塞、出血量、手术时间进行统计学处理。结果全部病例随访5~12个月,平均9个月,导航组11膝力线检测数据误差明显小于常规定位组11膝,导航组软组织平衡数据的角度变量、距离变量都明显小于常规定位组。两组都未发生脂肪栓塞。结论计算机导航技术用于膝关节骨性强直膝表面置换,使假体植入的更精确,软组织平衡更佳,与常规组有显著差异。但延长了手术时间。 Objective To compare the effects of Computer-assisted navigation (CAS) and conventional location technique in total knee arthroplasty (TKA). Methods Eight patients ( 11 knees) underwent CAS and 9 patients ( 11 knees) underwent conventional location technique for TKA. Follow-up was conducted for 5-12 months. The outcomes were compared. Results The mechanical axe error of the CAS group was ( 2. 14 ± 0. 25 ) °, significantly less than that of the conventional group [ ( 5.12 ± 2. 13 )°, P =0. 005 ]. The soft tissue balance angle variable of the CAS group was ( 1.04 ±0. 18) °, significantly less than that of the conventional group [ (4. 12 ± 1.72) ° ,P =0. 005 ]. The soft tissue separation variable of the CAS group was (3.4 ± 1.2) mm, significantly less than that of the conventional group [ (6. 1 ± 2. 4) mm, P =0. 005]. No fat embolism occurred in these 2 groups. The operating time of the CAS group was (82 ± 18) rain, significantly longer than that of the conventional group [ (59 ± 11 ) min, P = 0. 005 ]. Conclusion CAS causes more reliable artificial joint implantation and better soft-tissues balance, however, needs more operating time.
机构地区 沈阳市骨科医院
出处 《中华医学杂志》 CAS CSCD 北大核心 2007年第43期3035-3037,共3页 National Medical Journal of China
关键词 治疗 计算机辅助 关节成形术 置换 导航 Therapy,computer-assisted Arthroplasty,replacement, knee Navigation
  • 相关文献

参考文献13

  • 1Hacker RG, Stockheim M. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Rel Res, 2005,433 : 152-159.
  • 2Moreland JR, Bassett LW, Hanker GJ. Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am, 1987,69 : 745 -749.
  • 3Miehlke RK,Jenny JY,Kiefer H,et al. Computer aided total knee arthroplasty versus manual implantation technique. A multi-canter study. Poster AAOS, New Orleans,2003.
  • 4Mahaluxmivala J, Bankers MJ. The effect of surge on experience on component position in 673 press fit condylar posterior cruciate sacrificing total knee arthroplastied. J Arthoplasty ,21301,16 :635-640.
  • 5松田秀一,鍋山亮太郎,三浦裕正,ほか.膝關節のコソピュタ:支援手術.リウマチ科,2002,28:222-229.
  • 6Stulberg SD. How accurate is current TKR instrumentation. Clin Orthop Rel Res ,2003,416 : 177-184.
  • 7Mielke RK, Clemens U, Jens JH, et al. Navigation in knee endo prosthesis implantation preliminary experiences and prospective compare study with conventional implantation technique. Orthop IHre Grenzgeb,2001,139 : 109-116.
  • 8Jenny JY, Berci C. Computer-assisted implantation of a total knee arthroplasty: a case controlled study in comprision with classical instrumentation. Rev Chir Orthop Reoaratrice Appar Met.2001.87:645.
  • 9Bathis H. CT-free computer-assisted total knee arthroplasty versus the conventional technique: radiographic results of 100 cases. Orthopedics,2004, 27 : 476-480.
  • 10Townley CO. The anatomic total knee resurfacing arthroplasty. Clin Orthop Relat Res, 1985,192:82-96.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部