摘要 目的评价目前常规选择的标准监护Ⅱ导联和EASI12导联心电监测对于发现心肌缺血的有效性和敏感性。方法采用诊断试验的评价研究设计,将研究期间收住北京市宣武医院CCU病房的57例有ST段改变的病人作为病例组,43例无ST段改变的病人作为非病例组,选用标准12导联心电图为金标准,评价CCU标准监护Ⅱ导联和EASI12导联发现心肌缺血的有效性和敏感性。两组病人均同时描记标准12导联、EASI12导联和标准监护Ⅱ导联心电图。比较3种心电图中ST段的改变情况。结果标准监护Ⅱ导联心肌缺血检出率明显低于标准12导联心电图,敏感度、特异度、假阳性率和假阴性率分别为24.6%、95.3%、4.7%和75.4%,一致性检验Kappa值仅为0.178。而EASI12导联对心肌缺血的检出率与标准12导联心电图相仿,敏感度、特异度、假阳性率和假阴性率分别为89.5%、97.7%、2.3%和10.5%,Kappa=0.859。结论临床上通常选用的标准监护Ⅱ导联并不能有效地发现心肌缺血,而EASI12导联较标准Ⅱ导联能够更有效地发现心肌缺血,具有较好的敏感度和特异度。 Objective To evaluate the effectiveness and sensitivity of EASI 12-lead electrocardiogram (ECG) and standard monitor lead II ECG in detecting myocardial ischemia. Methods Diagnostic test evaluation design was used. Patients who were admitted to Xuanwu Hospital Cardiac Care Unit (CCU) were recruited for this pilot study and divided into ST-segment deviation group (n=57) and non-ST-segment deviation group (n=43) according to standard 12-lead ECG findings (golden standard). Standard 12-lead ECG, standard monitor lead II ECG strip and EASI 12-lead ECG were recorded simultaneously and ST segment deviation was compared. Results Monitor with standard lead II only had a lower detection rate of myocardial ischemia than standard 12-lead ECG, with a sensitivity and specificity of 24.6% and 95.3%, respectively, and the false negative rate is as high as 75.4% with a Kappa value of 0.178. The EASI 12-lead ECG had a good con-sistency with standard 12-lead ECG in detecting myocardial ischemia with a Kappa value of 0.859, sensitivity and specificity of 0. 859, 89.5% and 97. 7%, respectively, and a false negative rate of 10. 5%. Conclusion Standard monitor lead II , which is frequently selected by CCU nurses to monitor acute coronary syndrome patients usually can not detect myocardial ischemia effectively while the EASI 12-lead ECG is compatible with standard 12-lead ECG in detecting myocardial ischemia, indicating that monitor with EASI 12-lead ECG will more effectively detect myocardial ischemia than using standard monitor lead II only.
出处 《中华心律失常学杂志》 2007年第5期358-362,共5页 Chinese Journal of Cardiac Arrhythmias
基金 首都医科大学基础-临床合作项目(550020)
关键词 心电监护 EASI导联 心肌缺血 急性心肌梗死 Electorcardiograph monitor EASI 12-lead electorcardiogram monitoring Myocardial ische- mia Acute myocardial infarction
  • 相关文献

参考文献8

  • 1Leeper B. Continuous ST-Segment Monitoring. AACN Clin Issues, 2003,14 : 145-154.
  • 2Patton JA, Funk M. Survey of use of ST-segraent monitoring in patients with acute coronary syndromes. Am J Crit Care, 2001,10:23- 32.
  • 3Schroder K, Wegscheider K, Zeymer U, et al. Extent of ST-segment deviation in a single electrocardiogram lead 90 min after thrombolysis as a predictor of medium-term mortality in acute myocardial infarction. Lancet, 2001, 358 : 1479-1486.
  • 4Martinez EA, Kim LJ, Faraday N, et al. Sensitivity of routine intensive care unit surveillance for detecting myocardial ischemia. Crit Care Med, 2003, 31:2302-2308.
  • 5Landesberg G, Mosseri M, Wolf Y, et al. Perioperative myocardial ischemia and infarction: identification by continuous 12-lead electrocardiogram with online ST-segment monitoring. Anesthesiology, 2002, 96:264-270.
  • 6Antman EM, Anbe DT, Armstrong PW, et al. ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1999 Guidelines for the Management of Patients With Acute Myocardial Infarction). Circulation, 2004, 110: 588-636.
  • 7Dower GE, Yakush A, Nazzal SB, et al. Deriving the 12-lead electrocardiogram from four ( EASI ) electrodes. J Electrocardiol, 1988, 21 (Suppl) :S182-187.
  • 8Feild DQ, Feldman CL, Horacek BM. Improved EASI coefficients : their derivation, values, and performance. J Electrocardiol, 2002, 35(Suppl) : 23-33.

同被引文献3

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部