期刊文献+

多层螺旋CT在团注法增强的胰腺成像中的评价 被引量:11

Evaluation Value of Bolus Enhancement with Multi-slice helical CT in Pancreas
下载PDF
导出
摘要 目的探讨胰腺多层螺旋CT团注法增强的最佳时像和扫描方案。方法选取19例正常胰腺和23例胰腺癌病人,均行团注法增强扫描,比较胰腺组织在动脉期、胰腺期和门静脉期的强化程度、肿瘤同瘤旁正常胰腺组织的CT差值。结果正常胰腺在胰腺期强化最显著,高于动脉期和门静脉期(P<0.05),动脉期和门静脉期的强化程度相比较无明显差别(P>0.05);胰腺癌组三个时期的肿瘤同瘤旁正常胰腺组织的CT差值相比较中,胰腺期的CT差值最大(P<0.01),动脉期和门静脉期的CT差值相比较无差别(P>0.05)。结论胰腺团注法增强CT扫描中的胰腺期反映胰腺强化程度最佳,此期对胰腺癌的检出效果优于动脉期和门静脉期。 Objective To investigate the optimal temporal window and scanning scheme for pancreatic dynamic bolus enhanced with multi-slice helical CT scanning. Methods Dynamic bolus enhanced scanning of pancreas with MSCT were performed in 19 patients without pancreatic lesions and 23 with pancreatic carcinoma patient. And compared the enhancement degree of pancreatic parenchyma between arterial phase, pancreatic phase and portal phase, the value between the lesions and normal pancreas parenchyma was calculated. Results Enhancement value of normal pancreas was most prominent during pancreatic phase, than arterial phase and portal phase (P 〈0.05), no obvious difference was found statistically between arterial phase and portal phase ( P 〉0.05). In pancreatic carcinoma group, the A, value between the lesions and normal pancreas parenchyma during pancreatic phase was the greatest of all phase ( P 〈0.01), the difference was not found between arterial phase and portal phase ( P 〉0.05). Conclusion Pancreatic phase of dynamic bolus enhanced scanning of pancreas with MSCT was optimal temporal window in reflecting enhancement degree of pancreatic parenchyma, and had an advantage in finding out the lesions of pancreatic carcinoma than during arterial phase and portal phase.
出处 《中国CT和MRI杂志》 2007年第1期35-37,共3页 Chinese Journal of CT and MRI
基金 深圳市科技局科研基金资助项目 编号:200601015
关键词 胰腺 体层摄影术 X线计算机 增强 Pancreas Tomography, X-ray computed Enhancement
  • 相关文献

参考文献8

二级参考文献29

  • 1严福华,曾蒙,苏周,康荣.螺旋CT肝脏检查中技术参数的选择──时间-密度曲线的分析[J].临床放射学杂志,1996,15(5):290-293. 被引量:62
  • 2[1]Peters AM,Gunasekera RD, Henderson BL,et al. Non-invasive measurements of blood flow and extraction fraction.Nuclear Medicine Communications,1987, 8: 823-837.
  • 3[2]Peters AM,Brown J,Ilartnell GG,el al. Non-invasivc measurements of renal blood flow with 99mTc DTPA:a comparison with radiolabelled microspheres. Cardiovascular Research, 1987, 21:830-834.
  • 4[3]Miles KA. Measurement of tissue perfusion by dynamic computed tomography. B JR, 1991, 64: 409-412.
  • 5[4]Miles KA,Hayball M,Dixon AK.Colour perfusion imaging, a new application of computed tomography. Lancet, 1991, 337:643-645.
  • 6[5]Miles KA,Hayball MP, Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT.Radiology, 1993, 188: 405-411.
  • 7[6]Miles KA,Hayball MP,Dixon AK.Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging.BJR,1995, 68: 471-475.
  • 8[7]Miles KA,Leggett DA,Kelley BB,et al.In vivo assessment of neovascularization of liver metastases using perfusion CT. BJR, 1998, 71:276-281.
  • 9[8]Yoshito Tsushima,Yasushi Unno,Jun Koizumi,et al. Measurement of human hepatic and splenic perfusion using dynamic computed tomography: a preliminary report.Computer Methods and Programs in Biomedicine, 1998, 57: 143-146.
  • 10[9]Yoshito Tsushima,Shoichi Kusano.Age dependent decline in parenchymal perfusion in the normal human Dancreas: measurement by dynamic computed tomography,Pancreas, 1998, 17(2): 148-152.