期刊文献+

大气环境下多晶硅薄膜的疲劳性能 被引量:2

FATIGUE PROPERTY OF POLYSILICON THIN FILMS IN AMBIENT ENVIRONMENT
下载PDF
导出
摘要 为评估多晶硅薄膜材料的加载可靠性,发展一种新型多晶硅薄膜疲劳性能测试实验系统,利用片外测试方法研究多晶硅薄膜在大气环境下的拉伸疲劳特性。实验试件采用MEMS(micro-electro-mechanical systems)工艺制造,具有相同的长度、厚度和不同的宽度。每个加载条件下重复10次实验,应用Weibull方法对疲劳实验数据进行处理,得到0.35GPa~0.70GPa应力幅值范围内5个应力水平下多晶硅薄膜拉伸疲劳的S—N曲线。研究表明,多晶硅薄膜的疲劳寿命随着交变载荷幅值的减小而增大,二者呈对数线性关系。该结果可以直接用于多晶硅薄膜材料MEMS器件的可靠性设计。 In order to evaluate the reliability of loaded polysilicon thin films, a novel experimental system was developed to measure the fatigue property of polysilicon thin films. Using out-chip test method, the fatigue property of polysilicon thin films in ambient environment was successfully measured. The tested specimens were fabricated in MEMS (micro-electro-mechanical systems) process, which were same in length and thickness, but were different in width. In each load condition, the same experiment was carried out for 10 times. Finally the experimental data were processed with Weibull method to obtain the S- N curve of polysilicon thin films on 5 different stress levels in the peak stress range of 0.35 GPa - 0.70 GPa. The results showed that the fatigue life of polysilicon thin films increased with the decrease in the peak stress of the alternating load, and they were logarithmically linear, which might be helpful to the reliability design of polysilicon MEMS devices.
出处 《机械强度》 EI CAS CSCD 北大核心 2007年第6期919-922,共4页 Journal of Mechanical Strength
基金 国家自然科学基金项目(50525515) 中国基础研究项目(2003CB716205) 清华大学基础研究基金项目(Jc2003013)资助~~
关键词 微机电系统 多晶硅 薄膜 疲劳 Micro-electro-mechanical systems(MEMS) Polysilicon Thin film Fatigue
  • 相关文献

参考文献11

  • 1Connally J A, Brown S B. Slow crack growth in single-crystal Silicon. Science, 1992, 256:1 537 - 1 539.
  • 2苏才钧,吴昊,郭占社,孟永钢,温诗铸.单晶硅微构件力学特性片上测试系统[J].机械强度,2005,27(4):456-459. 被引量:4
  • 3Kapels H, Aigner R, Binder J. Fracture strength and fatigue of polysilicon determined by a novel thermal actuator. IEEE Trans Electron, Dec. 2000, 47:1 522 - 1 528.
  • 4Sharpe W N, Turner K T. Fatigue testing of materials used in microelectromechanical systems. Fatigue ' 99-Proceedings of the Seventh International Fatigue Congress, Beijing: Higher Education Press, 1999. 1 837 - 1 844.
  • 5Serre C. Measurement of micromechanical properties of polysilicon microstructures with an atomic force microscope. Sensors and Actuators, 1998, A 67 : 215 - 219.
  • 6Wu H, Meng Y G, Su C J, et al. An apparatus for measuring mechanical properties of microstructures in tensile mode. Science in China Series G- Physics and Mechanics & Astronomy, Jul. 2004, 47:127 - 132 Suppl. S.
  • 7Muhlstein C L, Stach E A, Ritchie R O. A reaction-layer mechanism for the delayed failure of micro-scale polycrystalline silicon structural films subjected to high-cycle fatigue loading. Acta Mater, 2002, 50:3 579 - 3 595.
  • 8Kahn H, Ballarini R, Mullen R L, et al. Electrostatically actuated failure of microfabricated polysilicon fracture mechanics specimens. Proc Roy Soc [C] Lond A, 1999, 455: 3807-3823.
  • 9Kahn H, Ballarini R, Heuer A H. Dynamic fatigue of silicon. Current Opinion in Solid State and Materials Science, 2004, 8:71 - 76.
  • 10Bagdahn J, Sharpe W N. Fatigue of polycrystalline silicon under long-term loading. Sensors and Actuators, 2003(A), 103(1-2): 9- 15.

二级参考文献22

  • 1邱宇,雷振坤,亢一澜,胡明,徐晗,牛红攀.微拉曼光谱技术及其在微结构残余应力检测中的应用[J].机械强度,2004,26(4):389-392. 被引量:13
  • 2Senturia S D. Microsystems design. Kluwer: Dordrecht, 2001.
  • 3Bagdahn J, Sharpe W N, Jadaan O. Fracture strength of polysilicon at stress concentrations. Journal of Microelectromechanical Systems, 2003, 12 (3): 302~312.
  • 4Connally J A, Brown S B. Slow crack growth in single-crystal silicon. Science, 1992, 256 (5063): 1537~1539.
  • 5Koskinen J. Microtensile testing of free-standing polysilicon fibers of various grain sizes . J. Micromech. Microeng, 1993, 3(1): 13~17.
  • 6Oliver W C, Pharr G M. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J. Mater. Res, 1992,(7): 1564~1583.
  • 7Edwards R L, Coles G, Sharpe W N. Comparison of tensile and bulge tests for thin-film silicon nitride. Experimental Mechanics, 2004, 44 (1): 49~54.
  • 8Weihs, T P, Hong S, Bravman J C, et al. Mechanical deflection of cantilever microbeams: A new technique for testing the mechanical properties of thin films. J. Mater. Res., 1988, 3: 931~942.
  • 9Moske M A, Ho P S, Mikalsen D J, et al. Measurement of thermal stress and stress relaxation in confined metal lines. I. Stresses during thermal cycling. Journal of Applied Physics, Aug 1, 1993, 74 (3):1716~1725.
  • 10Muhlstein C L, Brown S B, Ritchi R O. High-cycle fatigue and durability of polycrystalline silicon thin films in ambient air. Sensors and Actuators A, 2001, 94: 177~188.

共引文献9

同被引文献19

  • 1李秀娟,梁云虹,张志辉,任露泉.杨树叶片的微观结构及拉伸特性[J].吉林大学学报(工学版),2012,42(S1):440-443. 被引量:7
  • 2苏才钧,吴昊,郭占社,孟永钢,温诗铸.单晶硅微构件力学特性片上测试系统[J].机械强度,2005,27(4):456-459. 被引量:4
  • 3李跃光,姬战国.国内高频疲劳试验机的技术现状及其发展[J].试验技术与试验机,2006,46(1):1-4. 被引量:29
  • 4宝暄,李长春,刘晓东,张金英,顾凯.电液伺服疲劳试验机的力跟随控制[J].液压气动与密封,2006,26(6):1-3. 被引量:2
  • 5王喆垚.微系统设计与制造[M].北京:清华大学出版社,2008.
  • 6Tang W C,Nguyen T H,Judy M W,et al.Electrostatic-comb drive of lateral polysiliconresonators[J].Sensors and Actuators A:Phys.,1990,21(1/3):328-331.
  • 7Pisano A P,Cho Y H.Mechanical design issues inlaterally-driven microstructures[J].Sensors andActuators A:Phys.,1990,21/23:1060-1064.
  • 8Tabata O,Tsuchiya T,宋竞,等.MEMS可靠性[M].南京:东南大学出版社,2009.
  • 9Pandhumsoporn T.High etch rate,deep ansiotropicplasma etching of silicon for MEMS application[J].Proc.SPIE,1998,3328:93-101.
  • 10Laermer F,Schilp A.BOSCH deep silion etching:improving uniformity and etch of silicon for advancedMEMS Applications[C]//Proc.Twelfth IEEEInternational Conference on Micro Electro MechanicalSystems,1999:211-216.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部