摘要
为评价多平面经食道超声心动图(MTEE)定量诊断主动脉瓣狭窄(AS)的可行性和可靠性,在32例成年AS患者中应用经胸超声心动图(TTE)测量了主动脉瓣的瓣口面积(AVA-TTE),最大瞬时压差(PPG)和平均压差(MPG),应用MTEE测量了瓣口面积(AVA-TEE),并对手术治疗的患者直接测量了其瓣口面积(AVA-OPE)。结果显示:①AVA-TEE与AVA-TTE、AVA-TEE与AVA-OPE以及AVA-TTE与AVA-OPE间均高度相关(r分别为0.91、0.94、0.91),AVA-TTE显著高估AVA-OPE(P值<0.05);②MTEE对预测重度AS(AVA≤0.75cm2)的敏感性和特异性均为100%;③PPG、MPG与AVA-TTE和AVA-TEE间仅呈中度负相关(r=-0.73~-0.76),而与AVA-OVE间无相关关系。表明对于AS的定量诊断,MTEE具有高度的可行性和可靠性,而跨瓣压差存在明显的限制性。
To assess the feasibility and accuracy of multiplane transesophageal echocardiography (MTEE) in quantitative diagnosis of aortic stenosis (AS), 32 adult patients with AS were studied. The peak (PPG) and the mean (MPG) pressure gradients across the aortic valve were measured by transthoracic Doppler echocardiography (TTE), and the aortic valve area (AVA) was determined by TTE using the continuity equation, by planimetry of AVA with MTEE and by direct measurement during operation (OPE). The results showed that: 1. there were high correlations of AVA determined by MTEE and OPE(r=0.94), by MTEE and TTE (r=0.91), and by TTE and OPE (r=0.91). However, TTE consistantly overestimated OPE measurements (P<0.05); 2. both sensitivity and specificity of MTEE in predicting severe AS were 100%; 3. PPG and MPG correlated only negative moderately with AVA measurements (r=-0.73 ̄-0.76). It is concluded that MTEE provides a highly feasible and accurate technique, while pressure gradient measurements are less reliable for assessing the severity of AS.
出处
《中华超声影像学杂志》
CSCD
1997年第1期21-24,共4页
Chinese Journal of Ultrasonography