摘要
On the basis of analyzing pure refrigerants, this paper investigated the flow behavior of binary mixtures through a capillary tube. The design method of the capillary have been proposed. It have been verified by the experimental data that the method is agreed very well with pure and azeotropic mixtures, but there are some differences with nonazeotropic mixtures. This paper also suggested a correlation for the revision coefficient with Re.
On the basis of analyzing pure refrigerants, this paper investigated the flow behavior of binary mixtures through a capillary tube. The design method of the capillary have been proposed. It have been verified by the experimental data that the method is agreed very well with pure and azeotropic mixtures, but there are some differences with nonazeotropic mixtures. This paper also suggested a correlation for the revision coefficient with Re.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
1997年第4期493-496,共4页
Journal of Engineering Thermophysics