摘要 分析球铁不同组织与铁激性的相关性及电感式传感器应用于球铁件本体硬度检测的可行性,并就球铁大件表面粗糙度对检测信号的干扰程度进行了计算,证明其原理和方法能满足工程要求. The interrelation between the composition of nodular cast iron and ferromagnetic and the feasibility of applying inductance transducer to hardness testing of nodular cast iron are analyzed. The interference degree of surface roughness of nodular cast iron with testing signals is calculated. It is shown that the method can meet the needs of engineering.
出处 《无损检测》 1997年第6期159-161,共3页 Nondestructive Testing
  • 相关文献

同被引文献13

  • 1李家伟;陈积懋.无损检测手册[M]{H}北京:机械工业出版社,2002.
  • 2Bida G V,Nesterova O V. Magnetic Inspection of the Hardness of Cast-Iron Milling Rolls[J].{H}RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING,2008,(5):303-308.
  • 3Kikuchi H,Onuki T,Kamada Y. Initial Permeability and Vickers Hardness of Thermally Aged FeCu Alloy[J].{H}Journal of Magnetism and Magnetic Materials,2007.2886-2888.
  • 4李家伟;陈积懋.无损检测手册[M]北京:机械工业出版社,200225-26.
  • 5KIKUCHI H,ONUKI T,KAMADA Y. Initial permeability and vickers hardness of thermally aged Fe/Cu alloy[J].Journal of Magnetism and Magnetic Materials,2007.2886-2888.
  • 6MAKAROV A V,KOGAN L K,SCHASTLIVTSEV V M. Feasibility of testing hardness and wear resistance of eutectoid high-carbon steels with the structure of thin-plate pearlite by magnetic and electromagnetic methods[J].Russian Journal of Nondestructive Testing,2000,(08):539-550.
  • 7高晋占.微弱信号检测[M]北京:清华大学出版社,200432-35.
  • 8张玉华,罗飞路,孙慧贤.涡流检测中提离干扰的抑制[J].计量技术,2008(6):23-27. 被引量:5
  • 9高军哲,罗飞路,潘孟春,田武刚.基于AD9850和AD9854的涡流检测系统信号源设计[J].电子器件,2009,32(2):394-397. 被引量:1
  • 10贾昌磊,田明,王庆龙.铁磁材料硬度无损检测方法研究[J].长春理工大学学报(自然科学版),2009,32(2):217-219. 被引量:7

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部