摘要
针对某核电厂主泵-主管道焊缝材料冲击韧性偏低这一不符合项,根据目前我国的核安全法规和俄罗斯有关的标准规范并结合国际上通用的核标准,针对这一不符合项提出了自己的审评见解和解决方案。并对该核电厂今后的运行提出了安全要求。
For the non-conformance item on the value at the main coolant pipeline-reactor coolant pump tion scheme, based on the Chinese nuclear safety laws, al international nuclear standards. At the same time, we impact toughness value lower than the allowable welded joint we gave the review opinion and solu- Russian nuclear safety standards as well as gener- put forward the safety requirement for the nuclear power plant operation in future.
出处
《核安全》
2007年第1期8-12,共5页
Nuclear Safety
关键词
不符合项
审评
主泵-主管道焊缝
防脆断分析
LBB
non-conformance item
review
the main coolant pipeline-reactor coolant pump welded joint
analysis of brittle failure resistant of welded joint of main coolant pipeline-reactor coolant pump