摘要
在比较近年来国内外研制的各种类型变压器的基础上,结合国内城市电网发展的需要,对国内研制110kVSF6气体绝缘变压器的几个关键技术问题作了论述。结合国外SF6气体绝缘变压器的发展和国内的研制情况,对发展SF6气体绝缘变压器的几个关键技术问题作了介绍。
Based on a comparison to recently developed transformers of different kinds,this paper presents a comprehensive discussion for the inevitability of developing 110kV SF 6 gas insulated transformer in China, which has thoroughly considered the necessity of improving metropolitan power network. On the background of this field, some urgent technical issues are also analyzed for the investigation of 110kV SF 6 gas insulated transformer.
出处
《变压器》
北大核心
1997年第3期11-17,共7页
Transformer
关键词
气体绝缘变压器
有载分接开关
制造
变压器
Gas insulated transformer, SF 6,Cooling system, On-load tap changer