介绍了单相和三相多层并联干式空心电抗器计算方法、导线选择、温升计算公式、提高各层温升的均匀度和提高运算速度的措施,简述了抽头式电抗器的设计要点。
This paper introduces the calculation method,wire selection and formula for temperature rise of single-phase and three-phase multilayer shunt dry-type reactor with air core.And it makes mention of how to increase the uniformity of temperature rise and the speed of computation.It also deals with the principal aspects of designing tapped reactors briefly.
出处
《变压器》
北大核心
1997年第3期18-22,共5页
Transformer
关键词
空心电抗器
等效电阻
温升计算
设计
Reactor with air core,AC, Effective resistance,Temperature rise,Calculation