期刊文献+

高频有机聚合物SAW湿度传感器的研究 被引量:1

Study on the Moisture Sensor of High Frequency Surface Acoustic Wave Resonator Coated with Organic Polymer
下载PDF
导出
摘要 以双端口433.92 MHz的SAW谐振器(SAWR)为敏感元件,分别以聚乙烯吡咯烷酮(PVP)、磺基水杨酸(SSA)掺入PVP为敏感材料。对PVP掺杂前后湿度传感器的性能测试表明,沉积有PVP的SAWR感湿元件回复缓慢,可逆性差,而沉积SSA-PVP的感湿元件则表现出明显的可逆性,其响应速率和回复性明显均优于单一的PVP传感器,且响应频率与湿度表现出明显地线性相关性,其相关系数R可达0.996 21。 This article reports the preparation of the moisture sensor using 433.92 MHz two-port surface acoustic wave resonator as the sensoring element, which is coated with polyvinylpyrrolidone (PVP) or polyvinylpyrrolidone dopped with sulfosalicylic acid (SSA) respectively. The results at different relative humidity (RH) show that the resonator coated with PVP is poor in reversibility, while the resonator coated with PVP dopped with SSA is good in response and reversibility, which indicates better characteristics than the former. The relation between the responsing frequency shift and relative humidity has better linearity, and the linearly dependent coefficient R is up to 0. 996 21.
出处 《压电与声光》 CSCD 北大核心 2007年第6期625-627,共3页 Piezoelectrics & Acoustooptics
关键词 SAW传感器 双端口谐振型 聚乙烯吡咯烷酮 湿度传感器 surface acoustic wave sensor two-port resonator polyvinylpyrrolidone (PVP) moisture sensor
  • 相关文献

参考文献19

  • 1WHOLTJEN H, DESSY R. Surface acoustic wave probe for chemical analysis Ⅰ introduction and instrument description[J]. Anal Chem, 1979, 51 (9): 1458- 1464.
  • 2AVRAMOV I D, RAPP M, KUROSAWA S, et al. SAW and STW resonator operating at the same acoustic wave length[J]. IEEE Sensors Journal, 2002, 2 (3) : 150- 159.
  • 3MAUDER A. SAW gas sensors, comparison between delay line and two port resonator[J]. Sensors and Actuators B, 1995, 26(1-3): 187-190.
  • 4NIMAL A T, SINGH M, MITTAL U, et al. A comparative analysis of one-port Colpitt and two-port Pierce SAW oscillators for DMMP vapor sensing[J]. Sensors and Actuators B, 2006, 114(1) : 316-325.
  • 5DICKERT F L, FORTH P, BULST W E, et al. SAW devices-sensitivity enhancement in going from 80 MHz to 1 GHz[J].Sensors and Actuators B,1998, 46(2):120 -125.
  • 6PATEL S V, MLSNA T E, FRUHBERGER B, et al. Chemicapacitive microsensors for volatile organic com pound detection[J]. Sensors and Actuators B, 2003, 96(3): 541-553.
  • 7MCGILL R A, ABRAHAM M H, GRATE J W. Choosing polymer coatings for chemical sensors [J]. Chemtech, 1994, 24(9): 27-37.
  • 8HOPKINS A R, LEWIS N S. Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors for the nerve agent simulants dimethylmethylphosphonate and diisopropylmethylphosponate[J].Anal Chem, 2001, 73(5): 884-892.
  • 9LEVITSKY I, KRIVOSHLYKOV S G, GRATE J W. Rational design of a nile red/polymer composite film for fluorescence sensing of organophosphonate vapors using hydrogen bond acidic polymers[J]. Anal Chem, 2001, 73(14): 3 441- 3 448.
  • 10JURS P C, BAKKEN G A, MCCLELLAND H E. Computational methods for the analysis of chemical sensor array data from volatile analytes[J]. Chem Rev, 2000, 100(7): 2 649 -2 678.

同被引文献4