期刊文献+

Studies of surface plasmon resonance sensor using bi-beam differential measurement approach 被引量:1

Studies of surface plasmon resonance sensor using bi-beam differential measurement approach
下载PDF
导出
摘要 In this paper, a low-cost measurement approach with bi-beam was presented, which can be used for real-time detection and online analysis of solution refractive index, based on systematical analysis and experiments of conventional detection methods on surface plasmon resonance sensor. This novel method was analyzed theoretically and based on it a sensor system set was established. The factors that affect the sensor's sensitivity and working range were discussed. The angular adjustment setup was simplified, errors produced by movable components were avoided and the maneuverability was enhanced with this new method. The noiseproof feature and stability of the sensor system were greatly improved as well. In this paper, a low-cost measurement approach with bi-beam was presented, which can be used for real-time detection and online analysis of solution refractive index, based on systematical analysis and experiments of conventional detection methods on surface plasmon resonance sensor. This novel method was analyzed theoretically and based on it a sensor system set was established. The factors that affect the sensor's sensitivity and working range were discussed. The angular adjustment setup was simplified, errors produced by movable components were avoided and the maneuverability was enhanced with this new method. The noiseproof feature and stability of the sensor system were greatly improved as well.
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第12期2027-2031,共5页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 the Hi-Tech Research and Development Pro-gram (863) of China (No. 2006AA06Z406) the Natural ScienceFoundation of Zhejiang Province (No. Z504009), China
关键词 电波 能耗 计算方法 稳定性 Kretschmann prism structure, Light intensity, Bi-beam measurement, Light differential, Surface plasmon resonance
  • 相关文献

参考文献11

  • 1江秀明,陈志春,杨绍明,林贤福.光纤表面等离子体共振传感器研究进展[J].传感技术学报,2003,16(1):74-77. 被引量:12
  • 2Abdelmalek,F.Surface plasmon resonance based on Bragg gratings to test the durability of Au-Al films[].MaterLett.2002
  • 3Cai, Q,Li, X.,Chen, Y.Q.The history, actuality and prospect of surface plasmon resonance biosensor[].Foreign Med Sci (Biomed Eng Fascicle).1999
  • 4Esteban, O,Navarrete, M.C,Gonzalez-Cano, A.Simple model of compound waveguide structures used as optic sensors[].Optics & Lasers in Eng.2000
  • 5Jiang, X.M,Chen, Z.C,Yang, S.M.Progress of fiber optic sensor based on surfce plasmon resonance[].Chin J Sensors and Actuators.2003
  • 6Kambhampati, D.K,Knoll, W.Surface-plasmon optical techniques[].Current Opinion in Colloid & Interface Sci.1999
  • 7Kurihara, K,Suzuki, K.Theoretical understanding of an absorption-based surface plasmon resonance sensor based on Kretchmann’s theory[].Anal Chem.2002
  • 8Nelson, S.G,Johnston, K.S,Yee, S.S.High sensitivity surface plasmon resonance sensor based on phase detection[].Sensors and Actuators B.1996
  • 9Sharma, A.K,Gupta, B.D.Fibre-optic sensor based on surface plasmon resonance with Ag-Au alloy nanoparticle films[].Nanotechnology.2006
  • 10Toyama, S,Doumae, N.,Shoji, A,Lkariyama, Y.Design and fabrication of a waveguide-couple prism device for surface plasmon resonance sensor[].Sensors and Actuators B.2000

二级参考文献1

共引文献11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部