期刊文献+

优化水处理工艺去除有机污染物的效果研究 被引量:3

Optimization of Drinking Water Treatment Processes for Improvement of Organic Pollutants Removal Effect
下载PDF
导出
摘要 针对目前我国水源普遍受到有机污染的现状,进行了水处理工艺优化组合去除有机污染物的中试研究,重点考察了常规、预氧化+常规、常规+深度处理以及预氧化+常规+深度处理工艺对CODMn、消毒副产物前体物、生物稳定性以及遗传毒性的控制效果。结果表明,CODMn具有良好的代表性和可操作性,可作为水厂工艺选择和运行控制的主要参数;在常规工艺基础上增加臭氧—生物活性炭、活性炭等深度处理工艺是微污染源水处理工艺改进的主要方向。 Aimed at the current organic pollution problem in China, a pilot-scale study on the optimized combination of water treatment processes for removal of organic pollutants was performed. The control effects of the conventional process, preoxidation/conventional process, conventional process/advanced treatment, and preoxidation/conventional process/advanced treatment on CODMn, disinfection byproducts precursor, biostability and genetic toxicity were investigated emphatically. The results show that CODMn is a main representative index for process selection and operation control in waterworks. The com- bination of conventional process and advanced treatment of GAC or O3/BAC is an effective way to treat micropolluted source water.
出处 《中国给水排水》 CAS CSCD 北大核心 2007年第23期71-74,共4页 China Water & Wastewater
基金 国家高技术研究发展计划(863)项目(2002AA601140) 天津市科技创新专项基金资助项目(05FZZDSH00500)
关键词 给水处理 工艺优化 CODMN 消毒副产物 生物稳定性 water treatment process optimization CODMn disinfection by-products biostability
  • 相关文献

参考文献2

二级参考文献13

  • 1Reifferscheid G, Heil J. Validation of the SOS/umu test using test results of 486 chemicals and comparison with the Ames test and carcinogenicity data[J]. Mutation Res., 1996, 369: 129-145.
  • 2G Reifferscheid, J Hell, Y Oda, R K Zahn. Amicroplate version of the SOS/UMU-test for rapid detection of genotoxins and genotoxic potentials of environmental samples [ J ]. Mutation Res., 1991, 253, 215-222.
  • 3International Organization for Standardization. Water quality Determination of the genotoxicity of water and waste water using the umu-test[S]. Genf Switzerland: ISO/CD 13829,2000.
  • 4F Giuliani, T Koller, F E WiJrgler, R M Widmer. Detection of genotoxic activity in native hospital waste water by the umuC test[J]. MutationRes., 1996, 368:49-57.
  • 5W Z Whong, Y F Wen, J Stewart, T Orig. Validation of the SOS/umu-test with mutagenic complex mixtures[J]. Mutation Res.,1986, 175: 139-144.
  • 6Griffith J ,Riggan W B. Cancer mortality in U.S. counties with hazardous waste sites and ground water pollution [J]. Arch.Environ. Health, 1989,44 : 89 - 74.
  • 7Anderson S L, Harrison F L. Predicting the ecological significance of exposure to genotoxic substances in aquatic organisms[A]. In: Sandhu S S, et al. In Situ Evaluation of the Biological Hazards of Environmental Pollutants [C]. New York: Plenum Press, 1990. 81-93.
  • 8Ames B M, W E Durston, E Yamasaki, F D Lee. Carcinogens are mutagens: a simple test system combining liver homogenates for activation and bacteria for detection, Proc [ J ]. Proc. Natl.Acad. Sci. (U.S.A), 1973, 70:2281-2285.
  • 9Christoph Helma, Volker Mersch-Cundermann. Comparative evaluation of four bacterial assays for the detection of genotoxic effects in the dissolved water phases of aqueous matrices [ J ].Environ. Sci. Technol. , 1996, 30:897-907.
  • 10Ames B N, J McCann, E Yamasaki. Methods for detecting carcinogens and mutagens with the .Salmonella/Mammalian microsome mutagenicity test[J]. Mutation Res. , 1975, 31:347- 364.

共引文献13

同被引文献19

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部