期刊文献+

关于现行再生水水质标准和规范执行情况的讨论 被引量:11

Discussion on implementation of reclaimed water quality standards and design codes
下载PDF
导出
摘要 针对现行再生水水质标准、规范的执行情况进行了讨论,提出了再生水回用于工业循环冷却水时氨氮浓度控制在5mg/L以下,应根据现实情况近期适当降低某些城市河道的水体功能,在《城市污水再生利用城市杂用水水质》中列入部分能够全面反映水质安全的关键性指标,城市公共再生水尽量采用统一供水水质等一系列建议。 In this paper the implementation of five quality standards and design codes of reclaimed water is discussed and some suggestions are given. The concentration of NH3-N should be lower than 5 mg/L when the reclaimed water is used for industrial cooling water. To be convenient for scenic environment use, it is better to lower the water body function of some city rivers temporarily to a properly degree according to realistic circumstances. Some critical parameters which indicate the safety of reclaimed water are better to be included in the water quality standard. The urban public reclaimed water system is better to use a uniform water quality.
出处 《给水排水》 CSCD 北大核心 2007年第12期120-125,共6页 Water & Wastewater Engineering
关键词 再生水 水质标准 水质安全 回用 Reclaimed water Water quality standard Water quality safety Reuse
  • 相关文献

参考文献15

二级参考文献48

共引文献211

同被引文献111

引证文献11

二级引证文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部