摘要 目的:建立注射用对氨基水杨酸钠的细菌内毒素检查法。方法:参照《中国药典》2005年版二部细菌内毒素检查的定量测定法与凝胶限量法,对两种方法进行干扰实验。结果:通过对样品进行适当的稀释,凝胶法:样品浓度为2.5mg·ml^(-1)使用灵敏度为0.06EU·ml^(-1)的鲎试剂进行细菌内毒素检查无干扰作用;定量测定法:与凝胶法相同的样品浓度回收率较好,无干扰作用。结论:注射用对氨基水杨酸钠可以建立细菌内毒素检查法。 Objective: To develop the method of bacterial endotoxin test on amino sodium salicylate for injection. Method: The interference tests were performed to the quantitative test and gel limited method of bacterial endotoxin test included in CP 2005. Result: No interference was found when tested sample with concentration of 2.5 mg·ml^-1 and amehocyte lysate sensitivity of 0.06 EU.ml^- 1 in the gel limited method. The recovery was better than that of gel limited method when tested sample was same in the quantitative method and there were no interference also. Conclusion: Bacterial endotoxin test is applicable to amino sodium salieylate for injection.
出处 《中国药师》 CAS 2007年第12期1225-1226,共2页 China Pharmacist
关键词 注射用对氨基水杨酸钠 细菌内毒索检查 干扰作用 Amino sodium salieylate for injection Bacterial endotoxin test Interference
  • 相关文献

参考文献2

二级参考文献3

  • 1James F. Cooper.Resloving LAL Testing Interference[J].J Parent Sci Tech,1991,44(1):13-15
  • 2.中国药典[S]:2000年版: 二部[M].,.附录XIE,86.
  • 3朱焕杰 覃兵 冯聚锦.稀释剂(I)消除枸橼酸钠对细菌内毒素检查干扰的研究[J].药物分析杂志,1999,19:84-85.