摘要 针对隔磁段漏抗对潜油电机性能参数的影响,在电机特殊结构的基础上,建立了隔磁段的三维有限元数学模型,通过求解其磁场储能得到隔磁段处漏磁对应的漏抗。设计制造了模拟实验样机,实例对比直接验证了计算方法的准确性和可行性,表明了隔磁段漏抗对电机各性能参数均有较大的影响,在今后潜油电机的设计中必须予以考虑。 Aiming at the problem for the effect of leakage reactance in magnetic isolated segment to the performance parameter of submersible motor, 3D finity dement method(FEM) mathematic model of magnetic isolated segment based on the especial structure of submersible motor used to calculate leakage reactance corresponding to the leakage magnetic field in it is established in this paper. Imitation experiment model machine is designed and made. The accuracy and feasibility of the method described here is directly verified by example comparison. This leakage reactance has greater influence to performance parameter of the motor and must be taken into account in the design of submersible motor for the future.
出处 《电机与控制学报》 EI CSCD 北大核心 2007年第6期625-627,共3页 Electric Machines and Control
关键词 潜油电机 隔磁段 漏抗 模拟实验样机 直接验证 submersible motor magnetic isolated segment leakage reactance imitation experiment model machine direct verification
  • 相关文献

参考文献4

二级参考文献29

  • 1刘雷,刘卫红,马广明,耿会英.电潜螺杆泵采油系统及其现场应用[J].石油钻采工艺,2003,25(z1):30-32. 被引量:15
  • 2徐永明,孟大伟,李国辉.潜油电机机械损耗的分析与计算[J].电机与控制学报,2004,8(4):370-372. 被引量:16
  • 3戈宝军,张大魁,梁艳萍,李发海.能量变换器定子漏抗的分析与计算[J].电网技术,2005,29(3):15-17. 被引量:5
  • 4Biro O, Preis K. On the use of the magnetic vector potential in the finite element analysis of three-dimensional eddy currents [J].Trausactious on Magnetics, 1989, 25(4): 3154-3159.
  • 5Simonyi K, Theoretische elektrotechnik [M]. Berlin: VEB Deetscher Verlag der Wissenschaften, 1979.
  • 6Tegopoulos J A, Kriezis E E. Eddy current in linear conducting media[M]. Amsterdam: Elsevier Science Publishing Company Inc., 1985.
  • 7Thoren S, SSrqvist T, KjeUberg Met al. Powerformer-the firstcommercial turbo powerformer application [A]. CIGRE/SC 11-1 [C].Orlando, USA, 1999: 1-12.
  • 8Leijon M, Owman F. Powerformer-experience from the application of extruded solid dielectric cables in the stator winding of rotating machines[A]. 2000 IEEE Power Engineering Society Winter Meeting[C]. Piseataway, USA, 2000, 1: 736-744.
  • 9Leijon M, Aahlgren M, Walfridsson Let al. A recent development in the electrical insulation systems of generators and transformers[J]. IEEE Electrical Insulation Magazine, 2001, 17(3): 10-15.
  • 10Leijon M. Powerformer-a radically new rotating machine[J]. ABB Review, 1998, (2): 21-26.