摘要
应用池氏经椎弓多钉固定撑压装置矫治脊柱侧凸患者150例,Cobb角大于100°的侧凸矫正率为59.2%,50°~100°为68.63%,50°以下为76.71%。术中并发推弓定位不准2.4%,螺钉过长0.54%,胸膜和脊膜刺破0.27%,神经根损伤0.13%。术后并发断律为3.3%,断钉为0.41%,折弯为0.82%,脱出为0.41%,创口感染为2%,畸形复发率4%,假关节为3.3%。
150 cases of scoliosis were treated with Chi's rod and multi-screws fixation distraction-compression system via vertebral pedicle. The result showed that if the Cobb' s angle was over 100°, the mean correction rate was 59. 2%, if the Cobb's angle was within 50~100° the mean correction rate was 68. 63% and if the Cobb's angle was below 50°, the mean correction rate was 76.71%, The faults within the operation included imprecise drilling point (2. 4%), breaking of meninges and pleura (0. 27%), injury of nerve root (0. 13%). The mean complication rates after the operation were 3.3%of broking rod, O.41% of broking screws, 0. 82% of bending screws, 0. 41 % of lossening of screws,2% of infection of the incision,4% recurrence of the malformation and 3. 3% of pseudoarthrosis.
出处
《中国脊柱脊髓杂志》
CAS
CSCD
1997年第3期109-112,共4页
Chinese Journal of Spine and Spinal Cord