摘要
目的检测类风湿关节炎(RA)患者以及非RA的自身免疫性疾病患者血清中环瓜氨酸肽(CCP)抗体,探讨国产抗CCP抗体试剂盒在RA诊断中的敏感性和特异性。方法用酶联免疫吸附试验(ELISA)分别检测209例RA患者,82例非RA的其他自身免疫性疾病患者以及154名正常体检者的抗CCP抗体。结果以正常体检者组为对照,RA患者组抗CCP抗体的敏感性为72.25%,特异性为98.7%,阳性预测值为98.7%,阴性预测值为72.3%。以非RA自身免疫性疾病患者组为对照,RA患者组抗CCP抗体的敏感性为72.25%,特异性为76.83%,阳性预测值为88.8%,阴性预测值为52.0%。结论该抗CCP抗体的试剂盒对RA的诊断具有较高的敏感性和特异性,且操作简便,成本较低,有较高的临床应用价值。
Objective To observe the sensitivity and specificity of the anti-cyclic citrullinated peptide(CCP) antibody reagent kit in the diagnosis of rheumatoid arthritis (RA) by analyzing the anti-CCP in patients with RA and autoimmune diseases patients without RA. Methods Serum anti-CCP was determined by enzyme-linked immunosorbent assay (ELISA) in 209 RA patients, 82 non-RA patients and 154 normal control subjects. Results Comparing with the normal control subjects, the sensitivity and specificity of anti-CCP in the RA patients were 72.25% and 98.7%, and the positive and negative predictive values were 98.7% and 72.3%, respectively. Comparing with the non-RA patients, the sensitivity and specificity were 72.25% and 76.83% and the positive and negative predictive values were 88.8% and 52.0%, respectively. Conclusions The anti-CCP reagent kit made in China has better sensitivity and specificity in diagnosis of RA and higher clinical application value because of its easier operation and low cost.
出处
《检验医学》
CAS
北大核心
2007年第6期656-659,共4页
Laboratory Medicine