摘要 以变风量空调机组送风温度控制系统为对象,采用阶跃响应经验辨识方法建立了冷水阀开度-送风温度系统数学模型。针对该温度控制系统的纯延时特征,提出采用数字式PID+Smith预测控制算法改进控制质量,给出了该算法的流程图。应用Matlab对系统进行了仿真研究,结果表明该系统具有较强的鲁棒性。 Taking a supply air temperature control system as an object, establishes the mathematical model between the opening of chilled water valves and supply air temperature based on the step response empirical identification method. In view of the large delay of temperature control systems, introduces the digital PID control with Smith prediction algorithm to improve the control quality and gives the flow chart of control algorithm. The simulating result obtained with Matlab indicates that the system has fairly robust.
出处 《暖通空调》 北大核心 2007年第12期125-128,共4页 Heating Ventilating & Air Conditioning
关键词 变风量 空调机组 送风温度 PID控制 Smith预测 variable air volume, air conditioning unit, supply air temperature, PID control, Smith prediction
  • 相关文献

参考文献3

二级参考文献7

  • 1方崇智 萧德云.过程辨识[M].清华大学出版社,1989..
  • 2Ljung L, Yuan Z D. Asynptotic properties of black-box identification of transfer functions[J]. IEEE Transactions on Automatic Control, 1985,Ac-30(6): 514-530.
  • 3Zhu Y C. Multivariable process identification for MPC: the asymptotic method and its applications[J]. J Proc Cont, 1998,8(2): 101-115.
  • 4Qin S J, Badgwell T A. A survey of industrial model predictive control technology[J]. Control Engineering Practice, 2003,11:847-858.
  • 5Maciejowski J M. Predictive control with constraints[M].London: Pearson Education Limited, 2002.
  • 6Biegler L T, Nocedal J, Schmids C. Reduced hessian method for large-scale constrained optimization, 1995,5(2):314-347.
  • 7柯晶,钱积新.非线性离散时间系统的自适应函数观测器[J].电路与系统学报,2003,8(3):1-5. 被引量:2

共引文献44

同被引文献54

引证文献10

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部