期刊文献+

Dual Torch Plasma Arc Furnace for Medical Waste Treatment 被引量:2

Dual Torch Plasma Arc Furnace for Medical Waste Treatment
下载PDF
导出
摘要 In this paper, characteristics of a treatment and operated at atmospheric pressure dual torch plasma arc used for hazardous waste are studied, and also compared with those of the multi-torch plasma arc and the single torch plasma arc. The dual torch plasma arc is generated between the cathode and anode with argon as the working gas. The temperature distributions of the plasma arc are measured using a spectroscope and line pair method with the assumption of local thermodynamic equilibrium (LTE) for the DC arc current I=100 A and argon flow rate Q = 15 slpm. The measurements show that the temperatures of the dual torch arc plasma in the regions near the cathode, the anode and the center point are 10,000 K, 11,000 K and 9,000 K, respectively. And the high temperature region of the multi torch plasma arc is of double or much wider size than that of a conventional dual torch plasma arc and single plasma torch. Based on the preceding studies, a dual torch plasma arc furnace is developed in this study. The measured gas temperature at the center region of the argon arc is about 11,000 K for the case of I=200 A and Q=30 slpm operated in atmosphere. In this paper, characteristics of a treatment and operated at atmospheric pressure dual torch plasma arc used for hazardous waste are studied, and also compared with those of the multi-torch plasma arc and the single torch plasma arc. The dual torch plasma arc is generated between the cathode and anode with argon as the working gas. The temperature distributions of the plasma arc are measured using a spectroscope and line pair method with the assumption of local thermodynamic equilibrium (LTE) for the DC arc current I=100 A and argon flow rate Q = 15 slpm. The measurements show that the temperatures of the dual torch arc plasma in the regions near the cathode, the anode and the center point are 10,000 K, 11,000 K and 9,000 K, respectively. And the high temperature region of the multi torch plasma arc is of double or much wider size than that of a conventional dual torch plasma arc and single plasma torch. Based on the preceding studies, a dual torch plasma arc furnace is developed in this study. The measured gas temperature at the center region of the argon arc is about 11,000 K for the case of I=200 A and Q=30 slpm operated in atmosphere.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第6期709-712,共4页 等离子体科学和技术(英文版)
关键词 dual torch plasma arc furnace medical waste dual torch, plasma arc furnace, medical waste
  • 相关文献

参考文献14

  • 1Iwao T, Takizawa H, Inaba T, et al. 2005, Trans. The Iron and Steel Institute of Japan, 45:1084
  • 2Takizawa H, Iwao T, Inaba T. 2004, Plasma Application and Hybrid Functionally Materials, 13:17
  • 3Iwao T, Inaba T. 2002, Vacuum, 65:299
  • 4Iwao T, Miyazaki H, Inaba T. 2004, Vacuum, 73:359
  • 5Iwao T, Ishida T, Hayashi T, et al. 1999, Trans. J.Japan Inst. Metals, 63:15
  • 6Iwao T, Miyazaki H, Inaba T. 2002, Electrical Engineering in Japan, 139:1
  • 7Iwao T, Miyazaki H, Hayashi T, et al. 2000, Vacuum, 59:88
  • 8Liu Y, Qi H, Iwao T, et al. 2002, Vacuum, 65:463
  • 9Inaba T, Nagano M, Endo M. 1999, Electrical Engineering in Japan, 126:73
  • 10Inaba T, Iwao T. 2000, IEEE Trans. on Dielectrics and Electrical Insulation, 7:687

同被引文献23

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部