摘要 介绍了地源热泵在冬季运行供暖的实验研究,具体分析了长期连续运行时土壤温度的变化规律,热泵机组系统的COP变化情况,以及太阳能辅助系统与地源热泵系统联合运行时土壤温度的变化规律,热泵机组系统的COP变化情况。试验数据表明了增加太阳能辅助地源热泵系统后,显著地提高了冷凝器出口温度和室内温度,有效地提高了热负荷,增加了供热面积。总结出了本地区地源热泵系统的一般运行规律。 This article introduced the research on the performance of ground source heat pump system in winter. It analysed the changing pattern of the soil temperature and the COP of heat pump system when the system has a long-term continuous operation and when it jointly operated with the auxiliary solar heat system. The experiment data shows that the ground source heat pump system can raise the outlet water temperature of condenser and indoor temperature after it jointly operated with the auxiliary solar heat system.It is advantageous to raise its heating load, so it can increase heating area effectively. The article summarized the universal operation pattern of the ground source heat pump system in this area.
出处 《可再生能源》 CAS 2007年第6期47-50,共4页 Renewable Energy Resources
关键词 地源热泵 太阳能辅助系统 COP 供暖 ground source heat pump system auxiliary solar heat system COP heating