期刊文献+

应用MRI评估肾功能的研究进展 被引量:1

Approach to evaluation of renal function with MR imaging
原文传递
导出
摘要 MRI提供丰富的肾脏实质及大血管的形态学诊断信息及肾脏各项功能参数,近年来得到较大发展。就肾功能相关的各种MRI技术包括传统序列成像、血氧饱和依赖成像、弥散加权成像、动脉自旋标记等非定量分析方法;对比剂增强首次通过法、MR肾图等定量分析法进行了综述。 Due to its complementary information to standard morphological imaging, flmetional parameters, renal magnetic resonance imaging was developed rapidly these years. The purpose of this article is to review the recent studies of MR technology that renal function related, including traditional imaging sequence analysis, blood oxygenation level dependent imaging, diffusion weighted imaging, arterial spin labeling, contrast enhanced first-pass perfusion, MR renography.
出处 《国际放射医学核医学杂志》 2007年第5期311-314,共4页 International Journal of Radiation Medicine and Nuclear Medicine
关键词 磁共振成像 肾功能 比对剂 Magnetic resonance imaging Renal functional Contrast medium
  • 相关文献

参考文献21

  • 1Semelka RC, Corrigan K, Ascher SM, et al. Renal corticomedullary differentiation: observation in patients with differing serum creatinine levels. Radiology, 1994, 190(1): 149-152.
  • 2van den Dool SW, Wasser MN, de Fijter JW, et al. Functional renal volume: quantitative analysis at gadolinium-enhanced MR angiography-feasibility study in healthy potential kidney donors. Radiology, 2005, 236(1): 189-195.
  • 3Hauger O, Delalande C, Deminiere C, et al. Nephrotoxic nephritis and obstructive nephropathy: evaluation with MR imaging enhanced with ultrasmall superparamagnetic iron oxide-preliminary findings in a rat model. Radiology, 2000, 217(3): 819-826.
  • 4Grenier N, Pedersen M, Hauger O. Contrast agents for functional and cellular MRI of the kidney. Eur J Radiol, 2006, 60(3): 341-352.
  • 5Li LP, Storey P, Pierchala L,et al. Evaluation of the reproducibility of intrarenal R2* and DeltaR2* measurements following administration of furosemide and during waterload. J Magn Reson Imaging, 2004, 19(5): 610-616.
  • 6Afford SK, Sadowski EA, Unal O, et al. Delection of acute renal ischemia in swine using blood oxygen level-dependent magnetic resonance imaging. J Magn Reson Imaging, 2005, 22(3): 347-353.
  • 7Thoeny HC, Zumstein D, Simon-Zoula S. Functional evaluation of transplanled kidneys wilh diffusion-weighted and BOLD MR imaging : initial experience. Radiology, 2006, 241(3): 812-821.
  • 8Li L, Storey P, Kim D, et al. Kidneys in hypertensive rats show reduced response to nitric oxide synthase inhibition as evaluated by BOLD MRI. J Magn Reson Imaging, 2003, 17(6): 671-675.
  • 9Santosh T, Anthony V, Li Lp, et al. Evaluation of intrarenal oxygenation at 3.0 T using 3-dimensional multiple gradient-recalled echo sequence. Investigative Radiology, 2006, 41 (2): 181 - 184.
  • 10Pedersen M, Wen JG, Shi Y, et al. The effect of unilateral ureteral obstruction on renal function in pigs measured by diffusion-weighted MRI. APMIS Suppl, 2003, (109): 29-34.

同被引文献6

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部