摘要
采用MECC技术分离了环境毒物7种苯胺类化合物,考察了十二烷基硫酸钠 (SDS)溶液对分离的影响以及影响迁移时间和峰面积重现性的因素。各化合物迁移时间的相 对标准偏差RSD<0.5%,峰面积RSD<3.0%。在所测试的浓度范围内,具有很好的线性标 准曲线,苯胺化合物的最小检测量从0.82×10-12g到2.61×10-12g。将此法应用于废水中苯 胺类化合物的测定,结果令人满意。
A micellar electrokinetic capillary chromatography method (MECC) for the deter- mination of aniline derivatives in waste water was described. The effect of sodium dodecyl sulfate on the separation and factors influencing the repeatability of migration time and peak area were investigated. The RSD of migration time was less than 0. 5% and that of peak area was less than 3. 0%. The minimum detectable quantities of aniline derivatives varied from 0. 82*10-12 g to 2. 61×10-12 g. The method is simple, rapid and accurate.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1997年第7期839-843,共5页
Chinese Journal of Analytical Chemistry
关键词
胶束
电动毛细管色谱
废水
苯胺类化合物
MECC
Micellar electrokinetic capillary chromatography, waste water, aniline derivative