期刊文献+

16层螺旋CT灌注成像在原发性肝癌中的应用 被引量:3

Application of CT perfusion in primary hepatocellular carcinoma
下载PDF
导出
摘要 目的:探讨肝癌内部CT灌注特点及CT灌注成像在肝癌诊治中的应用价值。方法:对16例原发性肝癌共16个病灶的CT灌注参数进行分析。结果:灌注图像更真实显示病灶边缘。肝癌病灶中心BF、BV、HAP明显高于病灶边缘,MTT较边缘短,PS较边缘略低。结论:CT灌注成像对肝癌诊断及疗效评估、监测肿瘤复发方面具有重要价值。 Objective: To discuss the character and value of CT perfusion imaging in primary hepatocellular carcinoma with multislice helical CT. Methods: The parameters of 16 primary hepatocellular carcinoma focus confirmed by clinic were analyzed. Results: In CT perfusion images the boundary of tumors displayed more clearly. And the average parameter value of BF, BV, HAP in center focus is higher than the edge, but MTY was shorter and PS was a little lower than at the edge. Conclusion: CT perfusion imaging has significant value in diagnosing, inspecting curative effect and recrudescence of primary hepatocellular carcinoma.
出处 《中国临床医学影像杂志》 CAS 北大核心 2007年第12期863-866,共4页 Journal of China Clinic Medical Imaging
关键词 肝肿瘤 体层摄影术 X线计算机 liver neoplasms tomography, X-ray computed
  • 相关文献

参考文献14

  • 1Miles KA, Hayball M, Dixion AK. Colour perfusion imaging: a new application of computed tomography [J]. Lancet, 1991, 337 (8742): 643-645.
  • 2Eastwood JD, Lev MH, Azhari T, et al. CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke [J]. Radiology, 2002, 222 (1): 227-236.
  • 3Mateme R, Van Beers BE, Smith AM, et al. Noninvasive quan- tification of liver perfusion with dynamic computed tomography and a dualinput one compartmental model [J]. Clin Sci, 2000, 99 (6): 517-525.
  • 4Cuenod CA, Leconte I, Siauve N, et al. Early changes in liver perfusion caused by occult metastases in tats: detection with quantitative CT[J]. Radiology, 2001, 218(2): 556-561.
  • 5范光明,郭启勇.肝脏CT灌注成像的研究进展[J].中国医学影像技术,2004,20(2):298-301. 被引量:21
  • 6叶兆祥,宋秀宇,肖建宇.CT灌注成像在乳腺良、恶性病变诊断中的应用[J].中华放射学杂志,2005,39(10):1050-1054. 被引量:44
  • 7Dugdale PE, Miles KA, Bunce I, et al. CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response [J]. J Comput Assist Tomogr, 1999, 23: 540-547.
  • 8吕玉波,李传亭.螺旋CT灌注成像对肿瘤血管生成的评价[J].中国医学影像技术,2003,19(11):1573-1575. 被引量:14
  • 9晁宝婷,陈颉,巩若箴,柳澄.肝癌的螺旋CT灌注扫描[J].医学影像学杂志,2003,13(10):779-781. 被引量:6
  • 10郭俊渊.现代腹部影像诊断学[M].北京:科学出版社,2001:864-865.

二级参考文献74

  • 1赵心明,周纯武,吴宁,罗德红,黄遥,王建卫,孙伟,梁颖.胰腺多层螺旋CT灌注研究[J].中华放射学杂志,2003,37(9):845-849. 被引量:90
  • 2[1]Eastwood JD,Lev MH,Azhari T,et al. CT perfusion scanning with deconvolution analysis:pilot study in patients with acute middle cerebral artery stroke [J]. Radiology,2002,222(1):227-236.
  • 3[2]Furukawa M,Kashiwagi S,Matsunaga N,et al. Evaluation of cerebral perfusion parameters measured by perfusion CT in chronic cerebral ischemia: comparison with Xenon CT [J]. J Comput Assist Tomogr,2002,26(2):272-278.
  • 4[3]Miles KA,Heyball MP,Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT [J]. Radiology,1993,188(2):405-411.
  • 5[4]Blomley MJK,Coulden R,Dawson P,et al. Liver perfusion studied with ultrafast CT [J]. J Comput Assist Tomogr,1995,19(3):424-433.
  • 6[5]Materne R,Van Beers BE,Smith AM,et al. Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J]. Clin Sci,2000,99(6):517-525.
  • 7[6]Cuenod CA,Leconte I,Siauve N,et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT [J]. Radiology,2001,218(2):556-561.
  • 8[7]Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J].Br J Radiol,1991,64(761):409-412.
  • 9[8]Hindmarsh T. Elimination of water-soluble contrast media from the subarachnoid space: investigation with computed tomography [J]. Acta Radiol,1975,346(Suppl):45-49.
  • 10[9]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography [J]. Radiology,1980,137(3):679-686.

共引文献177

同被引文献26

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部