摘要
从渗水下排不畅,止水带接头不严,止水带、膨胀橡胶条周围不密实等方面分析了导致循环缝渗漏的原因,并提出了相应的渗漏预防措施,以使隧道收到良好的防水效果。
From congested drainage of seepage water, untight sealing of watertight strip and expanded rubber water stop and other aspects rea sons caused the leakage of circle joint are analyzed, at the same time corresponding seepage prevention measures are proposed, in order to real ize good seepage control effects.
出处
《山西建筑》
2007年第36期132-133,共2页
Shanxi Architecture
关键词
隧道
防渗漏技术
止水带
防水效果
tunnel, seepage prevention technology, watertight strip, waterproof effect