期刊文献+

试验机夹具的施力不均匀对弹性模量测定结果的影响 被引量:1

Test Mechine's Fixture Asymmetric Force Influence about Modulus of Elasticity Measurement
下载PDF
导出
摘要 本文介绍采用微机控制电子万能试验机的引伸计系统绘制力与变形弹性回归曲线,测定材料的弹性模量。通过对四个方向分别安装引抻计进行弹性模量测定的曲线和结果的分析,说明了万能试验机夹具的施力不均匀对测定结果的影响,提出了解决偏心影响的途径,对提高弹性模量测试精确度具有一定意义。 This article mainly introduces a tensile-gauge system of electronic universal test-machine applied to plot elastic recurrence curve of force-deformation, then gets the modulus of elasticity of material. According to the analysis of curve and data which gets from the tensile gauges setting in four different direction of test sample, indicates asymmetric force of the electronic universal testmachine clamp" influence to test data, giv, es some suggestion to increase test accuracy of modulus of elasticity based on above result.
作者 张云龙 熊攀
出处 《试验技术与试验机》 2007年第4期34-37,共4页 Test Technology and Testing Machine
关键词 试验机 夹具 电子引伸计 弹性模量 test-machine test fixture extensometer modulus of elasticity.
  • 相关文献

参考文献4

  • 1单辉祖.材料力学(Ⅰ)第2版.高等教育出版社.
  • 2郑文龙.材料力学实验.国防科学技术大学,2005.
  • 3GB/T228-2002.金属材料.室温拉仲试验方法
  • 4GB/T8553-1988.金属杨氏模量、弦线模量、切线模量和泊松比试验方法(静态法)

同被引文献5