摘要 通过对63例(66眼)眼内磁性异物B超下磁性试验的临床研究,结果显示:异物存留2周以内者阳性率较高为71.4%(P<0.05);位于玻璃体和晶体内的异物阳性率较高为68.08%(P<0.005)。而异物的大小及来源对磁性试验的结果无明显影响(P>0.5和P>0.1)。提示:异物所在位置及存留时间是影响B超下磁性试验的主要因素。同时分析了对眼内异物手术治疗的指导意义。 Sixty-three cases of the intraocular magnetic foreign (IOMFB) that magnetic tests were done under the B-scan were studied clinically. The results showed that the positive rate of the IOMFBS existing within two weeks was 71 .4%(P < 0.05). The positive rate of the IOMFBS in the vitreous and lenses was 68.08% (P < 0.005).The size and source of IOMFBS didn't affect the results of magnetic tests (P > 0. 5 and P > 0. 1 ) .This suggested that the principal factors affect the results of magnetic test are the position and the existing the of IOFBS. Meanwhile, the significance to direct the operation on IOMFBs was analysed.
出处 《眼外伤职业眼病杂志》 北大核心 1997年第4期251-252,共2页 Journal of Injuries and Occupational Diseases of the Eye with Ophthalmic Surgeries
关键词 眼内异物 磁性试验 磁性异物 超声波诊断 Intraocular foreign body Magnetic test Ultrasongraphy
  • 相关文献

参考文献1

  • 1蔡用舒,惠延年.眼球穿孔伤的病理观察[J]解放军医学杂志,1983(06).