期刊文献+

实时三维超声心动图测量二尖瓣闭合线的方法及其准确性研究 被引量:2

Measurement of mitral valve closure line by real time three-dimensional echocardiography and its accuracy evaluation
下载PDF
导出
摘要 目的探讨实时三维超声心动图技术对二尖瓣闭合线结构的成像和测量方法,寻找评价闭合线形态的定量指标,并验证测量方法的准确性。方法采用实时三维超声心动图技术对10只实验犬的活体心脏进行实时三维成像,将获得数据导入TomTec三维工作站对闭合线进行重建并分析。测量以下闭合线指标:①闭合线两端点之间的直线距离;②投影平面上的闭合线曲线长度;③闭合线中间段和侧段的两个夹角:命名为α和β角;最后测量离体心脏铅丝铸型标本的相对应指标,将两者进行比较。结果实时三维超声心动图对二尖瓣闭合线的各项测值与实际解剖标本对应的测值十分接近,并且具有很好的相关性与一致性。闭合线两端点之间的直线距离、投影平面上的曲线长度、α角和β角度数与实际测值之间相关系数r分别为0.857,0.839,0.755和0.748(P<0.05)。结论实时三维超声心动图技术能够较准确反映二尖瓣闭合线的形态结构,较适合用于二尖瓣闭合线形态学研究。 Objective To investigate the method and availability of analysis of mitral valve closure line by real time threedimensional echocardiography (RT-3DE), search the quantitive index and validate the accuracy of RT-3DE in measuring closure line. Methods Ten canine heart was imaged by three - dimensional echocardiography in vivo and then the full - volume images was input into TomTec workstation and analyzed oflline. Then the following indexes were measured: straight- line distance between the two end points, curve length in the projection plane, α and β angle. At last, all measurements derived from RT- 3DE were compared with cardiac specimen in vitro. Results The parameters derived from RT- 3DE were highly identical with the anatomical specimen. There were good correlation and concordance between RT- 3DE and the anatomical specimen. The coefficient correlation of straight - line dis- tance between the two end points, curve'length in the projection plane, α and β angle derived from RT- 3DE and specimen were 0. 857, 0.839, 0.755 and 0.748 ( P 〈 0.05). Conclusion RT - 3 DE technology can display the stucture of mitral valve closure line exactly and is fit to investigate the configuration of mitral valve closure line.
出处 《临床超声医学杂志》 2007年第12期705-708,共4页 Journal of Clinical Ultrasound in Medicine
关键词 超声心动描记术 三维 实时 二尖瓣 闭合线 Echocardiography Three-dimensional Real time Mitral valve Closure line
  • 相关文献

参考文献10

  • 1王新房.实时三维超声心动图——超声技术领域内的新突破[J].中华超声影像学杂志,2003,12(2):71-75. 被引量:99
  • 2Macnab A,Jenkins NP,Bridgewater BJ,et al.Three-dimensional echocardiography is superior to multiplane transoesophageal echo in the assessment of regurgitant mitral valve morphology.Eur J Echocardiography,2004,5(3):212 - 222.
  • 3Chan KL,Liu X,Ascah KJ,et al.Comparison of real-time three dimensional echocardiography with conventional two dimensioal echocardiography in the assessment of structural heart disease.J Am Soc Echocardiogr, 2004.17(9) :976 - 980.
  • 4Qin JX,Shiota T,Lever HM,et al.Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy:a real-time three-dimensional echocardiograhpic study.J Am Coll Cardiol,2002,39(2):308-314.
  • 5Sitges M,Jones M,Shiota T,et al.Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation:Validation experimental animal study and initial clinical experience.J Am Soc Echocardiogr,2003,16(1):38-46.
  • 6Goktekin O,Matsumura M,Omoto R,et al.Evaluation of mitral valve prolape using newly developed real-time three-dimensional echocardiographic system with real-time rendering.Int J Cardiovasc Imaging,2003,19(1):43-49.
  • 7Kwan J,Shiota T,Agler DA,et al.Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation.Real-time 3D echocardiography study .Circulation,2002,107(8):1135-1140.
  • 8Qin JX, Shiota T, McCarthy PM, et al. Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy:a real-time three-dimensional echocardiographic study.Circulation, 2003.9( 108 Suppl 1 ) : 11241 - 11246.
  • 9Zamorano J,Perez de Isla L,Sugeng L,et al.Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty:role of real-time 3D echocardiography.Eur Heart J,2004,25(23):2086-2091.
  • 10Kwan J,Qin JX,Popovi ZB,et al.Geometric changes of mitral annulus assessed by real-time 3-dimensional echocardiography:becoming enlarged and less nonplanar in the anteroposterior direction during systole in proportion to global left ventricular systolic function.J Am Soc Echocardiogr,2004,17(11):1179-1184.

二级参考文献4

共引文献98

同被引文献23

  • 1DeAnda A Jr,Kasirajan V,Higgins RS.Mitral valve replacement versus repair in 2003:where do we stand? Curr Opin Cardiol,2003,18(2):102-105.
  • 2Oppel UO,Stemmet F,Brink J,et al.Ischemic mitral valve surgery.J Heart Valve Dis,2000,9:64-74.
  • 3Nii M,Roman KS,Macgowan CK,et al.Insight into normal mitral and tricuspid annular dynamics in pediatrics:a real-time three-dimensional echocardiographic study.J Am Soc Echocardiogr,2005,18(8):805-814.
  • 4Macnab A,Jenkins NP,Bridgewater BJ,et al.Three-dimensional echocardiography is superior to multiplane transoesophageal echo in the assessment of regurgitant mitral valve morphology.Eur J Echocardiogr,2004,5(3):212-222.
  • 5Valocik G,Kamp O,Visser CA.Three-dimentional echocardiography in mitral valve disease.Eur J Echocardiogr,2005,6(6):443-454.
  • 6Davies MJ,Moore BP,Braimbridge MV.The floppy mitral valve:study of incidence,pathology,and complications in surgical,necropsy,and forensic material.Br Heart J,1978,40(5):468-481.
  • 7Carpentier A,Deloch A,Dauptain J,et al.A new reconstructive operation for correction of mitral and tricuspid insufficiency.J Thorac Cardiovasc Surg,1971,61(1):1-13.
  • 8Ranganathan N,Lam JH,Wigle ED,et al.Morphology of the human mitral valve Ⅱ the valve leaflets.Circulation,1970,41(3):459-467.
  • 9Flachskampf FA,Chandra S,Gaddipatti A,et al.Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction.J Am Soc Echocardiogr,2000,13(4):277-287.
  • 10Perloff JK,Roberts WC.The mitral valve apparatus:Functional anatomy of mitral regurgitation.Circulation,1972,46(2):227-239.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部