摘要 目的通过有限元方法对内收型股骨颈骨折的不同角度空心加压螺钉固定技术进行对比评价,判断何种技术更易发生转子下骨折,为临床应用提供理论依据。方法以内收型股骨颈骨折为研究对象建立有限元模型,模拟单腿站立时的受载和垂直力加载2种情况,对倒三角构型不同角度置钉技术分别进行有限元计算。结果第3模型在股骨干张力侧的最大Von-Mis-es应力明显高于其他模型,其他模型张力侧应力的差别都较小。结论倒三角构型时,单枚远钉低角度固定与传统高角度固定时发生转子下骨折的风险差别不大,只有三钉同时低角度固定时发生转子下骨折的可能性最大,建议临床避免低角度多钉固定。 Objective To compare different angle internal fixation for treatment of the adductive femoral neck fracture with cannulated compression screw with the finite element method, and evaluate the risk of subtrochanteric fracture of the complication of the internal fixation, and find out the rational fixation manner to guide clinical practice. Methods With the method of finite element analysis (FEA), the model was set up according to the adductive femoral neck fracture and the biomechanical features of the different angle fixations with three screws in an inverted triangular configuration were compared. The model of standing on one leg was simulated as the load situation and the vertical force to bending was also loaded. Results The third model was higher in the best Von- Mises stress than other models. It was less different among other models. Conclusion It' s most possible to cause subtrochanteric femur fracture in low - angle placement with all of three screws.
作者 徐刚
出处 《中国骨与关节损伤杂志》 2007年第12期984-986,共3页 Chinese Journal of Bone and Joint Injury
基金 温州市科技局基金资助项目(Y20060170)
关键词 股骨颈骨折 内固定 转子下骨折 生物力学 有限元分析 Femoral neck fracture Internal fixation Subtrochanteric fracture Biomechanies Finite element analysis
  • 相关文献

参考文献8

  • 1肖德明,曾纪葵,宋先.股骨颈骨折不同角度固定的生物力学比较研究[J].生物医学工程研究,1994,15(2):28-31. 被引量:4
  • 2许瑞杰,李涤尘,孙明林.内收型股骨颈骨折不同固定方式的生物力学分析[J].北京生物医学工程,2005,24(3):220-222. 被引量:6
  • 3Chaim SH, Mukherjee DP, Ggden AL, et al. A biomechanical study of femoral neck fracture fixation with the VHS Vari - Angle Hip Fixation System. Am J Orthop, 2002,31 ( 1 ) : 22
  • 4Kloen P, Rubel IF, Lyden JP, et al. Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: a report of four cases. J OrthopTrauma, 2003, 17:225
  • 5Maurer SG, Wright KE, Kummer FT, et al. Two or three screws for fixation of femoral neek fraetures? Am J Orthop, 2003, 32 (9) : 438
  • 6Selvan VT, Oakley MJ, Rangan A, et al. Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury, 2004, 5:136
  • 7Oakey JW, Stover MD, Suminers HD, et al. Does screw configuration affect subtrochanteric fracture after femoral neck fixation? Clin Orthop, 2006, 443:302
  • 8Pelet S, Leyvraz PF, Garofalo R, et al. Subor intertrochanteric fracture following screw fixation of an intracapsular proximal femoral fracture: true complication or technical error? Swiss Surg, 2003, 9: 82

二级参考文献6

共引文献7

同被引文献75

引证文献4

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部